Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA LE MODIFICHE in fondo alla pagina
Bicocca Open Archive
Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pileup of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pileup rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pileup events with a programmable wave-form generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pileup events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pileup pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pileup events with rise time of ∼15ms down to time separation between the individual events of about 2ms.
Armatol, A., Armengaud, E., Armstrong, W., Augier, C., Avignone, F., Azzolini, O., et al. (2021). Novel technique for the study of pileup events in cryogenic bolometers. PHYSICAL REVIEW C, 104(1) [10.1103/PhysRevC.104.015501].
Novel technique for the study of pileup events in cryogenic bolometers
Armatol A.;Armengaud E.;Armstrong W.;Augier C.;Avignone F. T.;Azzolini O.;Barabash A.;Bari G.;Barresi A.;Baudin D.;Bellini F.;Benato G.;Beretta M.;Berge L.;Biassoni M.;Billard J.;Boldrini V.;Branca A.;Brofferio C.;Bucci C.;Camilleri J.;Capelli S.;Cappelli L.;Cardani L.;Carniti P.;Casali N.;Cazes A.;Celi E.;Chang C.;Chapellier M.;Charrier A.;Chiesa D.;Clemenza M.;Colantoni I.;Collamati F.;Copello S.;Cremonesi O.;Creswick R. J.;Cruciani A.;D'Addabbo A.;D'Imperio G.;Dafinei I.;Danevich F. A.;De Combarieu M.;De Jesus M.;De Marcillac P.;Dell'Oro S.;Di Domizio S.;Dompe V.;Drobizhev A.;Dumoulin L.;Fantini G.;Faverzani M.;Ferri E.;Ferri F.;Ferroni F.;Figueroa-Feliciano E.;Formaggio J.;Franceschi A.;Fu C.;Fu S.;Fujikawa B. K.;Gascon J.;Giachero A.;Gironi L.;Giuliani A.;Gorla P.;Gotti C.;Gras P.;Gros M.;Gutierrez T. D.;Han K.;Hansen E. V.;Heeger K. M.;Helis D. L.;Huang H. Z.;Huang R. G.;Imbert L.;Johnston J.;Juillard A.;Karapetrov G.;Keppel G.;Khalife H.;Kobychev V. V.;Kolomensky Y. G.;Konovalov S.;Liu Y.;Loaiza P.;Ma L.;Madhukuttan M.;Mancarella F.;Mariam R.;Marini L.;Marnieros S.;Martinez M.;Maruyama R. H.;Mauri B.;Mayer D.;Mei Y.;Milana S.;Misiak D.;Napolitano T.;Nastasi M.;Navick X. F.;Nikkel J.;Nipoti R.;Nisi S.;Nones C.;Norman E. B.;Novosad V.;Nutini I.;O'Donnell T.;Olivieri E.;Oriol C.;Ouellet J. L.;Pagan S.;Pagliarone C.;Pagnanini L.;Pari P.;Pattavina L.;Paul B.;Pavan M.;Peng H.;Pessina G.;Pettinacci V.;Pira C.;Pirro S.;Poda D. V.;Polakovic T.;Polischuk O. G.;Pozzi S.;Previtali E.;Puiu A.;Ressa A.;Rizzoli R.;Rosenfeld C.;Rusconi C.;Sanglard V.;Scarpaci J.;Schmidt B.;Sharma V.;Shlegel V.;Singh V.;Sisti M.;Speller D.;Surukuchi P. T.;Taffarello L.;Tellier O.;Tomei C.;Tretyak V. I.;Tsymbaliuk A.;Velazquez M.;Vetter K. J.;Wagaarachchi S. L.;Wang G.;Wang L.;Welliver B.;Wilson J.;Wilson K.;Winslow L. A.;Xue M.;Yan L.;Yang J.;Yefremenko V.;Yumatov V.;Zarytskyy M. M.;Zhang J.;Zolotarova A.;Zucchelli S.
2021
Abstract
Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pileup of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pileup rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pileup events with a programmable wave-form generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pileup events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pileup pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pileup events with rise time of ∼15ms down to time separation between the individual events of about 2ms.
Armatol, A., Armengaud, E., Armstrong, W., Augier, C., Avignone, F., Azzolini, O., et al. (2021). Novel technique for the study of pileup events in cryogenic bolometers. PHYSICAL REVIEW C, 104(1) [10.1103/PhysRevC.104.015501].
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/325833
Citazioni
16
10
Social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2021-2023 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 598/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.