CUORE is a cryogenic experiment that focuses on the search of neutrinoless double beta decay in 130Te and it is located at the Gran Sasso National Laboratories. Its detector consists of 988 TeO2 crystals operating at a base temperature of ∼10 mK. It is the first ton-scale bolometric experiment ever realized for this purpose. Thanks to its large target mass and ultra-low background, the CUORE detector is also suitable for the search of other rare phenomena. In particular the low energy part of the spectra is interesting for the detection of WIMP-nuclei scattering reactions. One of the most important requirements to perform these studies is represented by the achievement of a stable energy threshold lower than 10 keV. Here, the CUORE capability to accomplish this purpose using a low energy software trigger will be presented and described.

Dompe, V., Adams, D., Alduino, C., Alfonso, K., Avignone, F., Azzolini, O., et al. (2020). Perspectives of lowering CUORE thresholds with Optimum Trigger. In 27th International Nuclear Physics Conference, INPC 2019. IOP Publishing Ltd [10.1088/1742-6596/1643/1/012020].

Perspectives of lowering CUORE thresholds with Optimum Trigger

Biassoni M.;Branca A.;Brofferio C.;Canonica L.;Capelli S.;Carniti P.;Chiesa D.;Clemenza M.;Cremonesi O.;Dell'Oro S.;Faverzani M.;Ferri E.;Fiorini E.;Giachero A.;Gironi L.;Gotti C.;Nastasi M.;Nucciotti A.;Nutini I.;Pattavina L.;Pavan M.;Pessina G.;Pozzi S.;Previtali E.;Puiu A.;Sisti M.;Terranova F.;
2020

Abstract

CUORE is a cryogenic experiment that focuses on the search of neutrinoless double beta decay in 130Te and it is located at the Gran Sasso National Laboratories. Its detector consists of 988 TeO2 crystals operating at a base temperature of ∼10 mK. It is the first ton-scale bolometric experiment ever realized for this purpose. Thanks to its large target mass and ultra-low background, the CUORE detector is also suitable for the search of other rare phenomena. In particular the low energy part of the spectra is interesting for the detection of WIMP-nuclei scattering reactions. One of the most important requirements to perform these studies is represented by the achievement of a stable energy threshold lower than 10 keV. Here, the CUORE capability to accomplish this purpose using a low energy software trigger will be presented and described.
paper
Physics
English
27th International Nuclear Physics Conference, INPC 2019 - JUL 29-AUG 02, 2019
2019
27th International Nuclear Physics Conference, INPC 2019
2020
1643
1
012020
none
Dompe, V., Adams, D., Alduino, C., Alfonso, K., Avignone, F., Azzolini, O., et al. (2020). Perspectives of lowering CUORE thresholds with Optimum Trigger. In 27th International Nuclear Physics Conference, INPC 2019. IOP Publishing Ltd [10.1088/1742-6596/1643/1/012020].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/460807
Citazioni
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
Social impact