A single gamma-ray spectrometer installed at the end of a collimator can be used to infer the total emission from a tokamak plasma if the transport of gamma-rays from the plasma to the detector is known. In such analysis, the plasma emission profile plays a fundamental role, since it impacts the fraction of plasma volume intercepted by the detector line of sight. In this work, the DT 17 MeV fusion gamma-rays emission profile of the JET discharge #99608 from second 46 to 48 has been estimated both with the TRANSP code and reconstructed through tomographic inversion based on the neutron camera data, assuming that fusion gamma-rays have the same profile as the 14 MeV fusion neutrons. The gamma-ray transport has been evaluated both by MonteCarlo simulations and analytical calculations. By combining MonteCarlo and analytical evaluations of the gamma-ray transport in different ways with the estimated radiation emission profile, we provide four different routes to determine the total gamma-ray yield from measurements whose results agree within better than 10%.
Marcer, G., Zohar, A., Dal Molin, A., Rigamonti, D., Rebai, M., Nocente, M., et al. (2023). Analytical and MonteCarlo approaches to infer the total gamma ray emission from the JET tokamak. JOURNAL OF INSTRUMENTATION, 18(5) [10.1088/1748-0221/18/05/C05020].
Analytical and MonteCarlo approaches to infer the total gamma ray emission from the JET tokamak
Marcer G.;Dal Molin A.;Rigamonti D.;Nocente M.;Panontin E.;Croci G.;Gorini G.;Muraro A.;Perelli Cippo E.;Putignano O.;Tardocchi M.
2023
Abstract
A single gamma-ray spectrometer installed at the end of a collimator can be used to infer the total emission from a tokamak plasma if the transport of gamma-rays from the plasma to the detector is known. In such analysis, the plasma emission profile plays a fundamental role, since it impacts the fraction of plasma volume intercepted by the detector line of sight. In this work, the DT 17 MeV fusion gamma-rays emission profile of the JET discharge #99608 from second 46 to 48 has been estimated both with the TRANSP code and reconstructed through tomographic inversion based on the neutron camera data, assuming that fusion gamma-rays have the same profile as the 14 MeV fusion neutrons. The gamma-ray transport has been evaluated both by MonteCarlo simulations and analytical calculations. By combining MonteCarlo and analytical evaluations of the gamma-ray transport in different ways with the estimated radiation emission profile, we provide four different routes to determine the total gamma-ray yield from measurements whose results agree within better than 10%.File | Dimensione | Formato | |
---|---|---|---|
10281-438838_VoR.pdf
accesso aperto
Tipologia di allegato:
Publisher’s Version (Version of Record, VoR)
Licenza:
Creative Commons
Dimensione
858.6 kB
Formato
Adobe PDF
|
858.6 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.