Stress is a major concern in microelectronic circuit production and Raman spectroscopy has proved to be an outstanding method for mapping it in silicon. In the literature, a configuration with two or three spectral dispersive stages is usually employed. By using a Raman spectrometer with a single dispersive stage, however, it is possible to have higher collection efficiency, resulting in fast acquisition and high stability of the system. Although the nominal spectral resolution of such a system is approximately 2 cm-1, we have found that the sensitivity to stress is less than 50 MPa, comparable to other systems with more dispersive stages. For low stress values, less than 100 MPa, the Raman measurements can be affected by the patterning of the sample itself, especially if laser plasma lines are used for spectral calibration. It will be shown that the use of a Raman microscope with a single dispersive stage, enabling simultaneous collection of Stokes and anti-Stokes components, provides a feedback for the reliability of the experiment.

Bonera, E., Fanciulli, M., Batchelder, D. (2002). Stress mapping in silicon: Advantages of using a Raman spectrometer with a single dispersive stage. APPLIED SPECTROSCOPY, 56(5), 560-563 [10.1366/0003702021955312].

Stress mapping in silicon: Advantages of using a Raman spectrometer with a single dispersive stage

BONERA, EMILIANO;FANCIULLI, MARCO;
2002

Abstract

Stress is a major concern in microelectronic circuit production and Raman spectroscopy has proved to be an outstanding method for mapping it in silicon. In the literature, a configuration with two or three spectral dispersive stages is usually employed. By using a Raman spectrometer with a single dispersive stage, however, it is possible to have higher collection efficiency, resulting in fast acquisition and high stability of the system. Although the nominal spectral resolution of such a system is approximately 2 cm-1, we have found that the sensitivity to stress is less than 50 MPa, comparable to other systems with more dispersive stages. For low stress values, less than 100 MPa, the Raman measurements can be affected by the patterning of the sample itself, especially if laser plasma lines are used for spectral calibration. It will be shown that the use of a Raman microscope with a single dispersive stage, enabling simultaneous collection of Stokes and anti-Stokes components, provides a feedback for the reliability of the experiment.
Articolo in rivista - Articolo scientifico
Stress; Raman spectroscopy
English
2002
56
5
560
563
none
Bonera, E., Fanciulli, M., Batchelder, D. (2002). Stress mapping in silicon: Advantages of using a Raman spectrometer with a single dispersive stage. APPLIED SPECTROSCOPY, 56(5), 560-563 [10.1366/0003702021955312].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/23510
Citazioni
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 18
Social impact