Among other neutron detector systems proposed as a possible substitute for 3He tubes, GEM-based ones have shown appealing characteristics, when coupled with suitable neutron-converter cathodes. In this paper, we present the results of a GEM-based neutron detector in a high-flux environment (the ORPHÉE reactor in Saclay), especially in terms of maximum rate capability and linearity. Recorded data show that the detector can manage neutron counting rates in the order of 50 × 106 counts/sec cm2 while maintaining a reasonable linearity and with no sign of instability.

Cippo, E., Croci, G., Muraro, A., Menelle, A., Albani, G., Cavenago, M., et al. (2015). A GEM-based thermal neutron detector for high counting rate applications. JOURNAL OF INSTRUMENTATION, 10(10) [10.1088/1748-0221/10/10/P10003].

A GEM-based thermal neutron detector for high counting rate applications

Croci, G;Muraro, A;Albani, G;Rebai, M;Gorini, G
2015

Abstract

Among other neutron detector systems proposed as a possible substitute for 3He tubes, GEM-based ones have shown appealing characteristics, when coupled with suitable neutron-converter cathodes. In this paper, we present the results of a GEM-based neutron detector in a high-flux environment (the ORPHÉE reactor in Saclay), especially in terms of maximum rate capability and linearity. Recorded data show that the detector can manage neutron counting rates in the order of 50 × 106 counts/sec cm2 while maintaining a reasonable linearity and with no sign of instability.
Articolo in rivista - Articolo scientifico
Micropattern gaseous detectors (MSGC, GEM, THGEM, RETHGEM, MHSP, MICROPIC, MICROMEGAS, InGrid, etc); Neutron detectors (cold, thermal, fast neutrons);
Micropattern gaseous detectors (MSGC, GEM, THGEM, RETHGEM, MHSP, MICROPIC, MICROMEGAS, InGrid, etc); Neutron detectors (cold, thermal, fast neutrons); Instrumentation; Mathematical Physics
English
2015
10
10
P10003
reserved
Cippo, E., Croci, G., Muraro, A., Menelle, A., Albani, G., Cavenago, M., et al. (2015). A GEM-based thermal neutron detector for high counting rate applications. JOURNAL OF INSTRUMENTATION, 10(10) [10.1088/1748-0221/10/10/P10003].
File in questo prodotto:
File Dimensione Formato  
JINST-RatebGEM.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 299.77 kB
Formato Adobe PDF
299.77 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/96415
Citazioni
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 14
Social impact