Circuit-level SPICE analysis of analog blocks in 28-nm bulk CMOS at doses approaching 1 Grad remains under-served. Device-centric characterizations and charge-based formalisms developed within TCAD rarely propagate into production EDA flows, leaving a lack of compact, SPICE-deployable models that represent radiation-induced degradation with sufficient fidelity and workflow alignment. BSIM RAD is proposed as a compact model base on BSIM that encapsulates Total Ionizing Dose damage by recasting oxide- and interface-trap contributions into an effective gate-oxide capacitance per unit area (C^'OX). The implementation is native to Cadence Virtuoso/Spectre, enabling drop-in use within standard verification setups. Calibration against measurements from 0 rad to 1 Grad covers nMOS/pMOS devices across distinct W/L sets and multiple V_DS values. Across this device matrix, the model reproduces the fractional shift in V_TH with sub-percent error and matches irradiated I_DS-V_GS characteristics within 2σ of the data, preserving the polarity-dependent displacement. The approach captures TID behavior to 1 Grad and beyond while maintaining parameter identifiability and CAD/EDA portability, closing a practical gap for global SPICE verification of radiation-tolerant analog circuits in 28-nm CMOS.

Gelmi, L., Barbaro, M., De Matteis, M. (2026). 28 nm MOS transistor SPICE BSIM model for simulating electrical effects of 1-Grad Total Ionizing Dose based on gate oxide capacitance. JOURNAL OF INSTRUMENTATION, 21(5) [10.1088/1748-0221/21/05/C05012].

28 nm MOS transistor SPICE BSIM model for simulating electrical effects of 1-Grad Total Ionizing Dose based on gate oxide capacitance

Gelmi L.;De Matteis M.
2026

Abstract

Circuit-level SPICE analysis of analog blocks in 28-nm bulk CMOS at doses approaching 1 Grad remains under-served. Device-centric characterizations and charge-based formalisms developed within TCAD rarely propagate into production EDA flows, leaving a lack of compact, SPICE-deployable models that represent radiation-induced degradation with sufficient fidelity and workflow alignment. BSIM RAD is proposed as a compact model base on BSIM that encapsulates Total Ionizing Dose damage by recasting oxide- and interface-trap contributions into an effective gate-oxide capacitance per unit area (C^'OX). The implementation is native to Cadence Virtuoso/Spectre, enabling drop-in use within standard verification setups. Calibration against measurements from 0 rad to 1 Grad covers nMOS/pMOS devices across distinct W/L sets and multiple V_DS values. Across this device matrix, the model reproduces the fractional shift in V_TH with sub-percent error and matches irradiated I_DS-V_GS characteristics within 2σ of the data, preserving the polarity-dependent displacement. The approach captures TID behavior to 1 Grad and beyond while maintaining parameter identifiability and CAD/EDA portability, closing a practical gap for global SPICE verification of radiation-tolerant analog circuits in 28-nm CMOS.
Articolo in rivista - Articolo scientifico
Models and simulations; Radiation damage evaluation methods; Radiation damage to electronic components; Radiation-hard electronics;
English
7-mag-2026
2026
21
5
C05012
open
Gelmi, L., Barbaro, M., De Matteis, M. (2026). 28 nm MOS transistor SPICE BSIM model for simulating electrical effects of 1-Grad Total Ionizing Dose based on gate oxide capacitance. JOURNAL OF INSTRUMENTATION, 21(5) [10.1088/1748-0221/21/05/C05012].
File in questo prodotto:
File Dimensione Formato  
Gelmi et al-2026-Journal of Instrumentation-VoR.pdf

accesso aperto

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Licenza: Creative Commons
Dimensione 718.07 kB
Formato Adobe PDF
718.07 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/631408
Citazioni
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
Social impact