A radiation shielding has been designed to reduce scattered neutrons and background gamma-rays for the new double-ring Time Of Flight Enhanced Diagnostics (TOFED). The shielding was designed based on simulation with the Monte Carlo code MCNP5. Dedicated model of the EAST tokamak has been developed together with the emission neutron source profile and spectrum; the latter were simulated with the Nubeam and GENESIS codes. Significant reduction of background radiation at the detector can be achieved and this satisfies the requirement of TOFED. The intensities of the scattered and direct neutrons in the line of sight of the TOFED neutron spectrometer at EAST are studied for future data interpretation. © 2014 AIP Publishing LLC.

Du, T., Chen, Z., Peng, X., Yuan, X., Zhang, X., Gorini, G., et al. (2014). Design of the radiation shielding for the time of flight enhanced diagnostics neutron spectrometer at Experimental Advanced Superconducting Tokamak. REVIEW OF SCIENTIFIC INSTRUMENTS, 85(11), 11E115 [10.1063/1.4891059].

Design of the radiation shielding for the time of flight enhanced diagnostics neutron spectrometer at Experimental Advanced Superconducting Tokamak

GORINI, GIUSEPPE;NOCENTE, MASSIMO;TARDOCCHI, MARCO;
2014

Abstract

A radiation shielding has been designed to reduce scattered neutrons and background gamma-rays for the new double-ring Time Of Flight Enhanced Diagnostics (TOFED). The shielding was designed based on simulation with the Monte Carlo code MCNP5. Dedicated model of the EAST tokamak has been developed together with the emission neutron source profile and spectrum; the latter were simulated with the Nubeam and GENESIS codes. Significant reduction of background radiation at the detector can be achieved and this satisfies the requirement of TOFED. The intensities of the scattered and direct neutrons in the line of sight of the TOFED neutron spectrometer at EAST are studied for future data interpretation. © 2014 AIP Publishing LLC.
Articolo in rivista - Articolo scientifico
Instrumentation
English
2014
85
11
11E115
11E115
none
Du, T., Chen, Z., Peng, X., Yuan, X., Zhang, X., Gorini, G., et al. (2014). Design of the radiation shielding for the time of flight enhanced diagnostics neutron spectrometer at Experimental Advanced Superconducting Tokamak. REVIEW OF SCIENTIFIC INSTRUMENTS, 85(11), 11E115 [10.1063/1.4891059].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/59038
Citazioni
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
Social impact