In the field of rare event physics, it is common to have huge masses of organic liquid scintillator as detection medium. In particular, they are widely used to study neutrino properties or astrophysical neutrinos. Thanks to its safety properties (such as low toxicity and high flash point) and easy scalability, linear alkyl benzene is the most common solvent used to produce liquid scintillators for large mass experiments. The knowledge of the refractive index is a pivotal point to understand the detector response, as this quantity (and its wavelength dependence) affects the Cherenkov radiation and photon propagation in the medium. In this paper, we report the measurement of the refractive index of the JUNO liquid scintillator between 260–1064 nm performed with two different methods to cover wide range of refractive index (an ellipsometer and a refractometer), with a sub percent level precision. In addition, we used an interferometer to measure the group velocity in the JUNO liquid scintillator and verify the expected value derived from the refractive index measurements.

Zhang, H., Beretta, M., Cialdi, S., Yang, C., Huang, J., Ferraro, F., et al. (2024). Refractive index in the JUNO liquid scintillator. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 1068(November 2024) [10.1016/j.nima.2024.169730].

Refractive index in the JUNO liquid scintillator

Barresi A.;Borghesi M.;Chiesa D.;Nastasi M.;Previtali E.;Sisti M.;
2024

Abstract

In the field of rare event physics, it is common to have huge masses of organic liquid scintillator as detection medium. In particular, they are widely used to study neutrino properties or astrophysical neutrinos. Thanks to its safety properties (such as low toxicity and high flash point) and easy scalability, linear alkyl benzene is the most common solvent used to produce liquid scintillators for large mass experiments. The knowledge of the refractive index is a pivotal point to understand the detector response, as this quantity (and its wavelength dependence) affects the Cherenkov radiation and photon propagation in the medium. In this paper, we report the measurement of the refractive index of the JUNO liquid scintillator between 260–1064 nm performed with two different methods to cover wide range of refractive index (an ellipsometer and a refractometer), with a sub percent level precision. In addition, we used an interferometer to measure the group velocity in the JUNO liquid scintillator and verify the expected value derived from the refractive index measurements.
Articolo in rivista - Articolo scientifico
Cherenkov light; JUNO experiment; Linear alkyl benzene; Neutrino physics; Refractive index; Scintillator;
English
10-ago-2024
2024
1068
November 2024
169730
open
Zhang, H., Beretta, M., Cialdi, S., Yang, C., Huang, J., Ferraro, F., et al. (2024). Refractive index in the JUNO liquid scintillator. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 1068(November 2024) [10.1016/j.nima.2024.169730].
File in questo prodotto:
File Dimensione Formato  
Zhang-2024-Nuclear Instruments and Methods in Physics Research-VoR.pdf

accesso aperto

Descrizione: CC BY 4.0 This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Licenza: Creative Commons
Dimensione 1.42 MB
Formato Adobe PDF
1.42 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/529882
Citazioni
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
Social impact