Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA LE MODIFICHE in fondo alla pagina
Bicocca Open Archive
The Jiangmen Underground Neutrino Observatory (JUNO) is a large neutrino detector currently under construction in China. JUNO aims to determine the neutrino mass ordering and to perform leading measurements detecting terrestrial and astrophysical neutrinos over a wide energy range, spanning from 200 keV to several GeV. Given the ambitious physics goals of JUNO, its readout electronics has to meet specific requirements, which motivated the thorough characterization described in this manuscript. The time synchronization among the electronics modules was found to exceed by few ns the theoretical expectation, as a consequence of the non-optimal data taking conditions. However, the system showed an excellent stability over long data taking periods, ensuring that any time offset could be calibrated out at the beginning of the data taking. The maximal deviation from a linear charge response was found to be 1.1% for the high gain ADC and 0.8% for the low gain ADC. In a JUNO-like environment, i.e 40 m underwater, the recorded FPGA temperature complied with the reliability standards of JUNO.
Cerrone, V., von Sturm, K., Bellato, M., Bergnoli, A., Bolognesi, M., Brugnera, R., et al. (2023). Validation and integration tests of the JUNO 20-inch PMT readout electronics. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 1053(August 2023) [10.1016/j.nima.2023.168322].
Validation and integration tests of the JUNO 20-inch PMT readout electronics
The Jiangmen Underground Neutrino Observatory (JUNO) is a large neutrino detector currently under construction in China. JUNO aims to determine the neutrino mass ordering and to perform leading measurements detecting terrestrial and astrophysical neutrinos over a wide energy range, spanning from 200 keV to several GeV. Given the ambitious physics goals of JUNO, its readout electronics has to meet specific requirements, which motivated the thorough characterization described in this manuscript. The time synchronization among the electronics modules was found to exceed by few ns the theoretical expectation, as a consequence of the non-optimal data taking conditions. However, the system showed an excellent stability over long data taking periods, ensuring that any time offset could be calibrated out at the beginning of the data taking. The maximal deviation from a linear charge response was found to be 1.1% for the high gain ADC and 0.8% for the low gain ADC. In a JUNO-like environment, i.e 40 m underwater, the recorded FPGA temperature complied with the reliability standards of JUNO.
Cerrone, V., von Sturm, K., Bellato, M., Bergnoli, A., Bolognesi, M., Brugnera, R., et al. (2023). Validation and integration tests of the JUNO 20-inch PMT readout electronics. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 1053(August 2023) [10.1016/j.nima.2023.168322].
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/459942
Citazioni
6
2
Social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 598/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.