Background and aims: The discordance between QRS voltages on electrocardiogram (ECG) and left ventricle (LV) wall thickness (LVWT) on echocardiogram (echo) is a recognized red flag (RF) of amyloid cardiomyopathy (AC) and can be measured by specific indexes. No head-to-head comparison of different ECG/echo indexes among subjects with echocardiographic suspicion of AC has yet been undertaken. The study aimed at evaluating the performance and the incremental diagnostic value of different ECG/echo indexes in this subset of patients. Methods: Electrocardiograms of subjects with LV hypertrophy, preserved ejection fraction and ≥ 1 echocardiographic RF of AC participating in the AC-TIVE study, an Italian prospective multicenter study, were independently analyzed by two cardiologists. Low QRS voltages and 8 different ECG/echo indexes were evaluated. Cohort specific cut-offs were computed. Results: Among 170 patients, 55 (32 %) were diagnosed with AC. Combination of low QRS voltages with interventricular septum ≥ 1,6 cm was the most specific (specificity 100 %, positive predictive value 100 %) ECG/echo index, while the ratio between the sum of all QRS voltages and LVWT <7,8 was the most sensitive and accurate (sensitivity 94 %, negative predictive value 97 %, accuracy 82 %). When the latter index was added to a model using easily-accessible clinical variables, the diagnostic accuracy for AC greatly increased (AUC from 0,84 to 0,95; p = 0,007). Conclusions: Among patients with non-dilated hypertrophic ventricles with normal ejection fraction and echocardiographic RF of AC, easily-measurable ECG/echo indexes, mainly when added to few clinical variables, can help the physician orient second level investigations. External validation of the results is warranted.

Pagura, L., Porcari, A., Cameli, M., Biagini, E., Canepa, M., Crotti, L., et al. (2023). ECG/echo indexes in the diagnostic approach to amyloid cardiomyopathy: A head-to-head comparison from the AC-TIVE study. EUROPEAN JOURNAL OF INTERNAL MEDICINE [10.1016/j.ejim.2023.09.026].

ECG/echo indexes in the diagnostic approach to amyloid cardiomyopathy: A head-to-head comparison from the AC-TIVE study

Crotti L.;Rella V.
Membro del Collaboration Group
;
Badano L.
Membro del Collaboration Group
;
Parati G.
Membro del Collaboration Group
;
2023

Abstract

Background and aims: The discordance between QRS voltages on electrocardiogram (ECG) and left ventricle (LV) wall thickness (LVWT) on echocardiogram (echo) is a recognized red flag (RF) of amyloid cardiomyopathy (AC) and can be measured by specific indexes. No head-to-head comparison of different ECG/echo indexes among subjects with echocardiographic suspicion of AC has yet been undertaken. The study aimed at evaluating the performance and the incremental diagnostic value of different ECG/echo indexes in this subset of patients. Methods: Electrocardiograms of subjects with LV hypertrophy, preserved ejection fraction and ≥ 1 echocardiographic RF of AC participating in the AC-TIVE study, an Italian prospective multicenter study, were independently analyzed by two cardiologists. Low QRS voltages and 8 different ECG/echo indexes were evaluated. Cohort specific cut-offs were computed. Results: Among 170 patients, 55 (32 %) were diagnosed with AC. Combination of low QRS voltages with interventricular septum ≥ 1,6 cm was the most specific (specificity 100 %, positive predictive value 100 %) ECG/echo index, while the ratio between the sum of all QRS voltages and LVWT <7,8 was the most sensitive and accurate (sensitivity 94 %, negative predictive value 97 %, accuracy 82 %). When the latter index was added to a model using easily-accessible clinical variables, the diagnostic accuracy for AC greatly increased (AUC from 0,84 to 0,95; p = 0,007). Conclusions: Among patients with non-dilated hypertrophic ventricles with normal ejection fraction and echocardiographic RF of AC, easily-measurable ECG/echo indexes, mainly when added to few clinical variables, can help the physician orient second level investigations. External validation of the results is warranted.
Articolo in rivista - Articolo scientifico
Amyloid cardiomyopathy; ECG/echo indexes; Echocardiography; Electrocardiogram; Left ventricular mass; Light chain amyloidosis; Red flags; Transthyretin amyloidosis; Voltages;
English
17-ott-2023
2023
none
Pagura, L., Porcari, A., Cameli, M., Biagini, E., Canepa, M., Crotti, L., et al. (2023). ECG/echo indexes in the diagnostic approach to amyloid cardiomyopathy: A head-to-head comparison from the AC-TIVE study. EUROPEAN JOURNAL OF INTERNAL MEDICINE [10.1016/j.ejim.2023.09.026].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/449819
Citazioni
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
Social impact