In this work we have characterised the K-edge digital subtraction angiography imaging system at the European Synchrotron Radiation Facility (ESRF, Grenoble, France). With this technique, after the minimally invasive intravenous injection of a contrast agent (iodine), two images are recorded simultaneously using monochromatic beams with energies bracketing the iodine K-edge. The image receptor consists of a two-line 432-pixel germanium detector. The logarithmic subtraction of the image set produced results in an iodine-enhanced image, where vessels are clearly visualised and contrast agent concentration can be precisely quantified. We have studied the imaging system in terms of the modulation transfer function, which was measured at the patient position, the 2-D normalised noise power spectrum, calculated for both raw and processed data, and the frequency-dependent detective quantum efficiency, which was calculated directly for final images. In addition, images of cylindrical phantoms with different concentrations of iodine, were also acquired.

Peterzol, A., Bravin, A., Coan, P., Elleaume, H. (2005). Performance of the K-edge digital subtraction angiography imaging system at the European synchrotron radiation facility. RADIATION PROTECTION DOSIMETRY, 117(1-3), 44-49 [10.1093/rpd/nci710].

Performance of the K-edge digital subtraction angiography imaging system at the European synchrotron radiation facility

Bravin A
Secondo
Membro del Collaboration Group
;
2005

Abstract

In this work we have characterised the K-edge digital subtraction angiography imaging system at the European Synchrotron Radiation Facility (ESRF, Grenoble, France). With this technique, after the minimally invasive intravenous injection of a contrast agent (iodine), two images are recorded simultaneously using monochromatic beams with energies bracketing the iodine K-edge. The image receptor consists of a two-line 432-pixel germanium detector. The logarithmic subtraction of the image set produced results in an iodine-enhanced image, where vessels are clearly visualised and contrast agent concentration can be precisely quantified. We have studied the imaging system in terms of the modulation transfer function, which was measured at the patient position, the 2-D normalised noise power spectrum, calculated for both raw and processed data, and the frequency-dependent detective quantum efficiency, which was calculated directly for final images. In addition, images of cylindrical phantoms with different concentrations of iodine, were also acquired.
Articolo in rivista - Articolo scientifico
K-edge digital subtraction; angiography; imaging system;
English
2005
117
1-3
44
49
reserved
Peterzol, A., Bravin, A., Coan, P., Elleaume, H. (2005). Performance of the K-edge digital subtraction angiography imaging system at the European synchrotron radiation facility. RADIATION PROTECTION DOSIMETRY, 117(1-3), 44-49 [10.1093/rpd/nci710].
File in questo prodotto:
File Dimensione Formato  
Peterzol-radprotdos-2006.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 241.18 kB
Formato Adobe PDF
241.18 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/345434
Citazioni
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 15
Social impact