Aflatoxins (AFs) B1, B2, G1 and G 2 were extracted from nuts by using pressurized liquid extraction (PLE) and the PLE extracts were analyzed using HPLC with fluorescence detection using photochemical post-column derivatization without further cleanup procedures. Several extraction parameters such as temperature (25, 40, 60 and 80°C), pressure (500, 1000, 1500 and 2000 psi), solvent extraction mixture (acetone, acetonitrile, ethyl acetate and methanol), number of cycles (1 and 2), use of dispersing agents and cell size (5 and 11 mL) were investigated for their effects on the extraction performance. The results showed 60°C, 1500 psi, acetonitrile, one cycle and a cell size of 5mL as most favorable PLE operating conditions. The proposed analytical method provides LODs below the maximum levels established by European Union regulations and the recoveries of the four AFs were between 77 and 93% at spiking levels of 4, 2 and 0.5 μg/kg for AFB1 and AFG1 and 1, 0.5 and 0.13 μg/kg for AFB2 and AFG2. Validation was carried out using certified reference materials. PLE has been applied for the first time to the analysis of AFs in nuts and offers the possibility for fast simple and accurate quantitative determination of studied mycotoxins. & 2009 WILEY-VCH Verlag GmbH & Co. KGaA

Campone, L., Piccinelli, A., Aliberti, L., Rastrelli, L. (2009). Application of pressurized liquid extraction in the analysis of aflatoxins B1, B2, G1 and G2 in nuts. JOURNAL OF SEPARATION SCIENCE, 32(21), 3837-3844 [10.1002/jssc.200900329].

Application of pressurized liquid extraction in the analysis of aflatoxins B1, B2, G1 and G2 in nuts

Campone L.;
2009

Abstract

Aflatoxins (AFs) B1, B2, G1 and G 2 were extracted from nuts by using pressurized liquid extraction (PLE) and the PLE extracts were analyzed using HPLC with fluorescence detection using photochemical post-column derivatization without further cleanup procedures. Several extraction parameters such as temperature (25, 40, 60 and 80°C), pressure (500, 1000, 1500 and 2000 psi), solvent extraction mixture (acetone, acetonitrile, ethyl acetate and methanol), number of cycles (1 and 2), use of dispersing agents and cell size (5 and 11 mL) were investigated for their effects on the extraction performance. The results showed 60°C, 1500 psi, acetonitrile, one cycle and a cell size of 5mL as most favorable PLE operating conditions. The proposed analytical method provides LODs below the maximum levels established by European Union regulations and the recoveries of the four AFs were between 77 and 93% at spiking levels of 4, 2 and 0.5 μg/kg for AFB1 and AFG1 and 1, 0.5 and 0.13 μg/kg for AFB2 and AFG2. Validation was carried out using certified reference materials. PLE has been applied for the first time to the analysis of AFs in nuts and offers the possibility for fast simple and accurate quantitative determination of studied mycotoxins. & 2009 WILEY-VCH Verlag GmbH & Co. KGaA
Articolo in rivista - Articolo scientifico
Aflatoxins; HPLC-fluorescence detection; Nuts; Pressurized liquid extraction
English
2009
32
21
3837
3844
none
Campone, L., Piccinelli, A., Aliberti, L., Rastrelli, L. (2009). Application of pressurized liquid extraction in the analysis of aflatoxins B1, B2, G1 and G2 in nuts. JOURNAL OF SEPARATION SCIENCE, 32(21), 3837-3844 [10.1002/jssc.200900329].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/267559
Citazioni
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 35
Social impact