Several compact neutron spectrometers are now installed at EAST (Experimental Advanced Superconducting Tokamak) to obtain information on fuel ions produced in the core of the plasma. In this paper, a stilbene crystal neutron spectrometer and an EJ301 liquid scintillator neutron spectrometer with n-γ discrimination capability will be discussed. Both spectrometers have a horizontal line of sight, while at different positions. In the last few experiment campaigns at EAST, they all proved to be reliable diagnostics for auxiliary heated D-D plasmas. Taking the response function simulated by dedicated Geant4 models into consideration, the velocity-space sensitivities given by the instrument-specific weight function of the beam-thermal part of neutron energy spectra in D-D plasmas are derived for both spectrometers with the Genesis code. This method makes it possible to directly relate the contribution of different deuteron velocity space regions to events in each channel of the neutron spectrum measured by the two instruments: http://rsi-htpd.peerx-press.org/.

Zhang, Y., Ge, L., Sun, J., Hu, Z., Nocente, M., Gorini, G., et al. (2018). Velocity-space sensitivity of the compact neutron emission spectrometers at EAST. REVIEW OF SCIENTIFIC INSTRUMENTS, 89(10), 1-5 [10.1063/1.5039393].

Velocity-space sensitivity of the compact neutron emission spectrometers at EAST

Nocente, M.;Gorini, G.;Tardocchi, M.;
2018

Abstract

Several compact neutron spectrometers are now installed at EAST (Experimental Advanced Superconducting Tokamak) to obtain information on fuel ions produced in the core of the plasma. In this paper, a stilbene crystal neutron spectrometer and an EJ301 liquid scintillator neutron spectrometer with n-γ discrimination capability will be discussed. Both spectrometers have a horizontal line of sight, while at different positions. In the last few experiment campaigns at EAST, they all proved to be reliable diagnostics for auxiliary heated D-D plasmas. Taking the response function simulated by dedicated Geant4 models into consideration, the velocity-space sensitivities given by the instrument-specific weight function of the beam-thermal part of neutron energy spectra in D-D plasmas are derived for both spectrometers with the Genesis code. This method makes it possible to directly relate the contribution of different deuteron velocity space regions to events in each channel of the neutron spectrum measured by the two instruments: http://rsi-htpd.peerx-press.org/.
Articolo in rivista - Articolo scientifico
Magnetically confined plasmas, neutron spectroscopy
English
2018
89
10
1
5
10I141
none
Zhang, Y., Ge, L., Sun, J., Hu, Z., Nocente, M., Gorini, G., et al. (2018). Velocity-space sensitivity of the compact neutron emission spectrometers at EAST. REVIEW OF SCIENTIFIC INSTRUMENTS, 89(10), 1-5 [10.1063/1.5039393].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/213841
Citazioni
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
Social impact