We report a study of the CUORE sensitivity to neutrinoless double beta (0) decay. We used a Bayesian analysis based on a toy Monte Carlo (MC) approach to extract the exclusion sensitivity to the 0 decay half-life (T1/20ν) at 90 % credibility interval (CI) – i.e. the interval containing the true value of T1/20ν with 90 % probability – and the 3σ discovery sensitivity. We consider various background levels and energy resolutions, and describe the influence of the data division in subsets with different background levels. If the background level and the energy resolution meet the expectation, CUORE will reach a 90 % CI exclusion sensitivity of 2 · 10 25 year with 3 months, and 9 · 10 25 year with 5 years of live time. Under the same conditions, the discovery sensitivity after 3 months and 5 years will be 7 · 10 24 year and 4 · 10 25 year, respectively.
Alduino, C., Alfonso, K., Artusa, D., Avignone, F., Azzolini, O., Banks, T., et al. (2017). CUORE sensitivity to 0 decay. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS, 77(8) [10.1140/epjc/s10052-017-5098-9].
CUORE sensitivity to 0 decay
Biassoni, M.;Branca, A.;Brofferio, C.;Canonica, L.;Capelli, S.;Carniti, P.;Cassina, L.;Chiesa, D.;Clemenza, M.;Cremonesi, O.
;Faverzani, M.;Ferri, E.;Fiorini, E.;Giachero, A.;Gironi, L.;Gorla, P.;Gotti, C.;Maino, M.;Nastasi, M.;Nones, C.;Nucciotti, A.;Pattavina, L.;Pavan, M.;Pessina, G.;Pozzi, S.;Previtali, E.;Sisti, M.;Terranova, F.;Zanotti, L.;
2017
Abstract
We report a study of the CUORE sensitivity to neutrinoless double beta (0) decay. We used a Bayesian analysis based on a toy Monte Carlo (MC) approach to extract the exclusion sensitivity to the 0 decay half-life (T1/20ν) at 90 % credibility interval (CI) – i.e. the interval containing the true value of T1/20ν with 90 % probability – and the 3σ discovery sensitivity. We consider various background levels and energy resolutions, and describe the influence of the data division in subsets with different background levels. If the background level and the energy resolution meet the expectation, CUORE will reach a 90 % CI exclusion sensitivity of 2 · 10 25 year with 3 months, and 9 · 10 25 year with 5 years of live time. Under the same conditions, the discovery sensitivity after 3 months and 5 years will be 7 · 10 24 year and 4 · 10 25 year, respectively.File | Dimensione | Formato | |
---|---|---|---|
10281-175807.pdf
accesso aperto
Tipologia di allegato:
Publisher’s Version (Version of Record, VoR)
Dimensione
1.1 MB
Formato
Adobe PDF
|
1.1 MB | Adobe PDF | Visualizza/Apri |
Alduino2017_Article_CUORESensitivityTo0NuBetaBeta0.pdf
Solo gestori archivio
Tipologia di allegato:
Publisher’s Version (Version of Record, VoR)
Dimensione
1.1 MB
Formato
Adobe PDF
|
1.1 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.