After an introduction on the various experimental techniques to be adopted in searches for double beta decay, the new approach based on the use of cryogenic low temperature detectors is described. The present results are reported on the limit for neutrinoless double beta decay of <sup>130</sup>Te obtained with the large bolometric detector CUORICINO. This setup consists of 44 cubic crystals of natural TeO<sub>2</sub> with 5 cm sides and 18 crystals of 3×3×6 cm<sup>3</sup>. Four of these latter crystals are made with isotopically enriched materials: two in <sup>128</sup>Te and two others in <sup>130</sup>Te. With a sensitive mass of 40.7 kg, this array is by far the most massive running cryogenic detector. The array is operated at a temperature of ∼10 mK in a dilution refrigerator under a heavy shield in the Gran Sasso Underground Laboratory at a depth of about 3500 m.w.e. The counting rate in the region of neutrinoless double beta decay is 0.18±0.02 counts keV <sup>-1</sup> kg<sup>-1</sup> y<sup>-1</sup>, among the lowest in this type of experiment. No evidence for neutrinoless double beta decay is found. The corresponding lower limit for the lifetime of this process is 2×10<sup>24</sup> years at 90% C.L. The resultant upper limit on the effective neutrino mass ranges between 0.2 and 1.0 eV, depending on the theoretically calculated nuclear matrix elements. This constraint is the most restrictive one, except for those obtained with Ge diodes, and is comparable to them. The second part of this report is devoted to the present status of the construction of the larger experiment CUORE (Cryogenic Underground Observatory for Rare Events) formed from 988 bolometers with a cubic TeO<sub>2</sub> absorber of size 5×5×5 cm<sup>3</sup>, with a total mass of ∼750 kg. We present technical details of the CUORE setup as well as of its location and our efforts to reduce radioactive backgrounds. © 2006.

Ardito, R., Arnaboldi, C., Artusa, D., Avignone III, F., Balata, M., Bandac, I., et al. (2006). The CUORICINO and CUORE double beta decay experiments. PROGRESS IN PARTICLE AND NUCLEAR PHYSICS, 57(1), 203-216 [10.1016/j.ppnp.2005.11.030].

The CUORICINO and CUORE double beta decay experiments

ARNABOLDI, CLAUDIO;BROFFERIO, CHIARA;CAPELLI, SILVIA;CAPOZZI, FRANCESCA;CLEMENZA, MASSIMILIANO;Cremonesi, O;FIORINI, ETTORE;GORLA, PAOLO;NONES, CLAUDIA;NUCCIOTTI, ANGELO ENRICO LODOVICO;PAVAN, MAURA;Pirro, S;Previtali, E;SISTI, MONICA;ZANOTTI, LUIGI ERNESTO
2006

Abstract

After an introduction on the various experimental techniques to be adopted in searches for double beta decay, the new approach based on the use of cryogenic low temperature detectors is described. The present results are reported on the limit for neutrinoless double beta decay of 130Te obtained with the large bolometric detector CUORICINO. This setup consists of 44 cubic crystals of natural TeO2 with 5 cm sides and 18 crystals of 3×3×6 cm3. Four of these latter crystals are made with isotopically enriched materials: two in 128Te and two others in 130Te. With a sensitive mass of 40.7 kg, this array is by far the most massive running cryogenic detector. The array is operated at a temperature of ∼10 mK in a dilution refrigerator under a heavy shield in the Gran Sasso Underground Laboratory at a depth of about 3500 m.w.e. The counting rate in the region of neutrinoless double beta decay is 0.18±0.02 counts keV -1 kg-1 y-1, among the lowest in this type of experiment. No evidence for neutrinoless double beta decay is found. The corresponding lower limit for the lifetime of this process is 2×1024 years at 90% C.L. The resultant upper limit on the effective neutrino mass ranges between 0.2 and 1.0 eV, depending on the theoretically calculated nuclear matrix elements. This constraint is the most restrictive one, except for those obtained with Ge diodes, and is comparable to them. The second part of this report is devoted to the present status of the construction of the larger experiment CUORE (Cryogenic Underground Observatory for Rare Events) formed from 988 bolometers with a cubic TeO2 absorber of size 5×5×5 cm3, with a total mass of ∼750 kg. We present technical details of the CUORE setup as well as of its location and our efforts to reduce radioactive backgrounds. © 2006.
Articolo in rivista - Articolo scientifico
Double beta decay; Neutrino mass
English
2006
57
1
203
216
none
Ardito, R., Arnaboldi, C., Artusa, D., Avignone III, F., Balata, M., Bandac, I., et al. (2006). The CUORICINO and CUORE double beta decay experiments. PROGRESS IN PARTICLE AND NUCLEAR PHYSICS, 57(1), 203-216 [10.1016/j.ppnp.2005.11.030].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/14048
Citazioni
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 8
Social impact