Measurements of sun-induced chlorophyll fluorescence (SIF) over plant canopies provide a proxy for plant photosynthetic capacity and are of high interest for plant research. Together with spectral reflectance, SIF has the potential to act as a noninvasive approach to quantify photosynthetic plant traits from field to air and spaceborne scales. However, SIF is a small signal contribution to the reflected sunlight and often not distinguishable from sensor noise. SIF estimation is, therefore, affected by an unquantified uncertainty, making it difficult to estimate accurately how much SIF is truly emitted from the plant. To investigate and overcome this, we designed a device based on a spectrometer covering the visible range and equipped it with an LED emitting at the wavelength of SIF. Using this as a reference and applying thorough calibrations, we present consistent evidence of the instrument's capability of SIF retrieval and accuracy estimations. The LED's intensity was measured under sunlight with 1.27 ± 0.27 m W× sr<sup>-1</sup> m}s nm<sup>-1</sup> stable over the day. The large increase of SIF due to the Kautsky effect was measured spectrally and temporally proving the biophysical origin of the signal. We propose rigorous tests for instruments intended to measure SIF and show ways to further improve the presented methods.

Burkart, A., Schickling, A., Mateo, M., Wrobel, T., Rossini, M., Cogliati, S., et al. (2015). A Method for Uncertainty Assessment of Passive Sun-Induced Chlorophyll Fluorescence Retrieval Using an Infrared Reference Light. IEEE SENSORS JOURNAL, 15(8), 4603-4611 [10.1109/JSEN.2015.2422894].

A Method for Uncertainty Assessment of Passive Sun-Induced Chlorophyll Fluorescence Retrieval Using an Infrared Reference Light

ROSSINI, MICOL
;
COGLIATI, SERGIO
;
JULITTA, TOMMASO
Penultimo
;
2015

Abstract

Measurements of sun-induced chlorophyll fluorescence (SIF) over plant canopies provide a proxy for plant photosynthetic capacity and are of high interest for plant research. Together with spectral reflectance, SIF has the potential to act as a noninvasive approach to quantify photosynthetic plant traits from field to air and spaceborne scales. However, SIF is a small signal contribution to the reflected sunlight and often not distinguishable from sensor noise. SIF estimation is, therefore, affected by an unquantified uncertainty, making it difficult to estimate accurately how much SIF is truly emitted from the plant. To investigate and overcome this, we designed a device based on a spectrometer covering the visible range and equipped it with an LED emitting at the wavelength of SIF. Using this as a reference and applying thorough calibrations, we present consistent evidence of the instrument's capability of SIF retrieval and accuracy estimations. The LED's intensity was measured under sunlight with 1.27 ± 0.27 m W× sr-1 m}s nm-1 stable over the day. The large increase of SIF due to the Kautsky effect was measured spectrally and temporally proving the biophysical origin of the signal. We propose rigorous tests for instruments intended to measure SIF and show ways to further improve the presented methods.
Articolo in rivista - Articolo scientifico
chlorophyll; fluorescence; LED; reference; spectroscopy;
chlorophyll; fluorescence; LED; reference; spectroscopy; Electrical and Electronic Engineering; Instrumentation
English
2015
15
8
4603
4611
7086007
none
Burkart, A., Schickling, A., Mateo, M., Wrobel, T., Rossini, M., Cogliati, S., et al. (2015). A Method for Uncertainty Assessment of Passive Sun-Induced Chlorophyll Fluorescence Retrieval Using an Infrared Reference Light. IEEE SENSORS JOURNAL, 15(8), 4603-4611 [10.1109/JSEN.2015.2422894].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/85612
Citazioni
  • Scopus 36
  • ???jsp.display-item.citation.isi??? 30
Social impact