Scintillation crystals have a wide range of applications in detectors for high energy and medical physics. They are recquired to have not only good energy resolution, but also excellent time resolution. In medical applications, L(Y)SO crystals are commonly used for time of flight positron emission tomography (TOF-PET). This study aims at determining the experimental and theoretical limits of timing using L(Y)SO based scintillators coupled to silicon photomultipliers (SiPMs). Measurements are based on the time-over-threshold method in a coincidence setup utilizing the ultra-fast amplifier-discriminator NINO and a fast oscilloscope. Using a 2 × 2 × 3 mm3 LSO:Ce codoped 0.4% Ca crystal coupled to a commercially available SiPM (Hamamatsu S10931-050P MPPC), we achieve a coincidence time resolution (CTR) of 108±5ps FWHM measured at E=511keV. We determine the influence of the data acquisition system to 27±2ps FWHM and thus negligible as compared to the CTR. This shows that L(Y)SO scintillators coupled to SiPM photodetectors are capable of achieving very good time resolution close to the desired 100ps FWHM for TOF-PET systems. To fully understand the measured values, we developed a simulation tool in MATLAB that incorporates the timing properties of the photodetector, the scintillation properties of the crystal and the light transfer within the crystal simulated by SLITRANI. The simulations are compared with measured data in order to determine their predictive power. Finally we use this model to discuss the influence of several important parameters on the time resolution like scintillation rise- and fall time and light yield, as well as single photon time resolution (SPTR) and the detection efficiency of the SiPM. In addition we find the influence of photon travel time spread in the crystal not negligible on the CTR, even for the used 2 × 2 × 3 mm 3 geometry. © CERN 2013.

Gundacker, S., Auffray, E., Frisch, B., Jarron, P., Knapitsch, A., Meyer, T., et al. (2013). Time of flight positron emission tomography towards 100ps resolution with L(Y)SO: An experimental and theoretical analysis. JOURNAL OF INSTRUMENTATION, 8(7), P07014-P07014 [10.1088/1748-0221/8/07/P07014].

Time of flight positron emission tomography towards 100ps resolution with L(Y)SO: An experimental and theoretical analysis

PIZZICHEMI, MARCO
Penultimo
;
2013

Abstract

Scintillation crystals have a wide range of applications in detectors for high energy and medical physics. They are recquired to have not only good energy resolution, but also excellent time resolution. In medical applications, L(Y)SO crystals are commonly used for time of flight positron emission tomography (TOF-PET). This study aims at determining the experimental and theoretical limits of timing using L(Y)SO based scintillators coupled to silicon photomultipliers (SiPMs). Measurements are based on the time-over-threshold method in a coincidence setup utilizing the ultra-fast amplifier-discriminator NINO and a fast oscilloscope. Using a 2 × 2 × 3 mm3 LSO:Ce codoped 0.4% Ca crystal coupled to a commercially available SiPM (Hamamatsu S10931-050P MPPC), we achieve a coincidence time resolution (CTR) of 108±5ps FWHM measured at E=511keV. We determine the influence of the data acquisition system to 27±2ps FWHM and thus negligible as compared to the CTR. This shows that L(Y)SO scintillators coupled to SiPM photodetectors are capable of achieving very good time resolution close to the desired 100ps FWHM for TOF-PET systems. To fully understand the measured values, we developed a simulation tool in MATLAB that incorporates the timing properties of the photodetector, the scintillation properties of the crystal and the light transfer within the crystal simulated by SLITRANI. The simulations are compared with measured data in order to determine their predictive power. Finally we use this model to discuss the influence of several important parameters on the time resolution like scintillation rise- and fall time and light yield, as well as single photon time resolution (SPTR) and the detection efficiency of the SiPM. In addition we find the influence of photon travel time spread in the crystal not negligible on the CTR, even for the used 2 × 2 × 3 mm 3 geometry. © CERN 2013.
Articolo in rivista - Articolo scientifico
Analysis and statistical methods; Photoemission; Photon detectors for UV, visible and IR photons (solid-state) (PIN diodes, APDs, Si-PMTs, G-APDs, CCDs, EBCCDs, EMCCDs etc); Scintillators, scintillation and light emission processes (solid, gas and liquid scintillators); Instrumentation; Mathematical Physics
English
2013
8
7
P07014
P07014
P07014
none
Gundacker, S., Auffray, E., Frisch, B., Jarron, P., Knapitsch, A., Meyer, T., et al. (2013). Time of flight positron emission tomography towards 100ps resolution with L(Y)SO: An experimental and theoretical analysis. JOURNAL OF INSTRUMENTATION, 8(7), P07014-P07014 [10.1088/1748-0221/8/07/P07014].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/72400
Citazioni
  • Scopus 109
  • ???jsp.display-item.citation.isi??? 102
Social impact