Neutron GEM-based detectors represent a new frontier of diagnostic devices in neutron-linked physics applications such as detectors for fusion experiments (Croci et al., 2012 [1]) and spallation sources (Murtas et al., 2012 [2]). Besides, detectors installed in HEP experiments (like LHC at CERN) are dip in a high flux neutron field. For example, the TOTEM T2 GEM telescope (Bagliesi et al., 2010 [3]) at LHC is currently installed very close to the beam pipe where a high intensity (>104ncm-2s-1) neutron background is present. In order to assess the capability (particularly related to discharge probability) of working in intense neutrons environment, a 10×10cm2 Triple GEM detector has been tested using a high flux (105ncm-2s-1) neutron beam. The neutron-induced discharge probability PDisch was measured to be 1.37×10 -7 at an effective gain G=5×104. In addition, the different types of neutron interactions within the detector were fully explained through a GEANT4 simulation. © 2013 Elsevier B.V.

Croci, G., Alfonsi, M., Ropelewski, L., Tsipolitis, G., Fanourakis, G., Ntomari, E., et al. (2013). Discharge probability measurement of a Triple GEM detector irradiated with neutrons. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 712, 108-112 [10.1016/j.nima.2013.02.014].

Discharge probability measurement of a Triple GEM detector irradiated with neutrons

CROCI, GABRIELE
Primo
;
2013

Abstract

Neutron GEM-based detectors represent a new frontier of diagnostic devices in neutron-linked physics applications such as detectors for fusion experiments (Croci et al., 2012 [1]) and spallation sources (Murtas et al., 2012 [2]). Besides, detectors installed in HEP experiments (like LHC at CERN) are dip in a high flux neutron field. For example, the TOTEM T2 GEM telescope (Bagliesi et al., 2010 [3]) at LHC is currently installed very close to the beam pipe where a high intensity (>104ncm-2s-1) neutron background is present. In order to assess the capability (particularly related to discharge probability) of working in intense neutrons environment, a 10×10cm2 Triple GEM detector has been tested using a high flux (105ncm-2s-1) neutron beam. The neutron-induced discharge probability PDisch was measured to be 1.37×10 -7 at an effective gain G=5×104. In addition, the different types of neutron interactions within the detector were fully explained through a GEANT4 simulation. © 2013 Elsevier B.V.
Articolo in rivista - Articolo scientifico
Discharge probability; Neutrons; Triple GEM; Instrumentation; Nuclear and High Energy Physics
English
2013
712
108
112
open
Croci, G., Alfonsi, M., Ropelewski, L., Tsipolitis, G., Fanourakis, G., Ntomari, E., et al. (2013). Discharge probability measurement of a Triple GEM detector irradiated with neutrons. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 712, 108-112 [10.1016/j.nima.2013.02.014].
File in questo prodotto:
File Dimensione Formato  
NIMA-DischNeut.pdf

accesso aperto

Dimensione 1.05 MB
Formato Adobe PDF
1.05 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/63598
Citazioni
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 22
Social impact