Solid state detectors and low-temperature calorimeters are widely employed in rare event searches, because of their excellent sensitivity and consequent low energy threshold. A common procedure to establish the energy threshold is to define the trigger level at a fixed number of baseline standard deviations (sigmas) above the baseline level, typically 3σ or 5σ. This is not an ideal option when the threshold becomes a critical parameter for the detectors, requiring an optimised definition of the trigger. Recorded events with a small amplitude-to-noise ratio likely survive the selection criteria of the analysis chain contributing to the experiment background. We present a method to quantify the lowest trigger threshold achievable as a function of the acceptable amount of noise events triggered for the physics case under investigation. We then apply this novel method to existing experimental and simulated data to validate the model we presented.

Mancuso, M., Bento, A., Ferreiro Iachellini, N., Hauff, D., Petricca, F., Probst, F., et al. (2019). A method to define the energy threshold depending on noise level for rare event searches. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 940(1 October 2019), 492-496 [10.1016/j.nima.2019.06.030].

A method to define the energy threshold depending on noise level for rare event searches

Ferreiro Iachellini N.;
2019

Abstract

Solid state detectors and low-temperature calorimeters are widely employed in rare event searches, because of their excellent sensitivity and consequent low energy threshold. A common procedure to establish the energy threshold is to define the trigger level at a fixed number of baseline standard deviations (sigmas) above the baseline level, typically 3σ or 5σ. This is not an ideal option when the threshold becomes a critical parameter for the detectors, requiring an optimised definition of the trigger. Recorded events with a small amplitude-to-noise ratio likely survive the selection criteria of the analysis chain contributing to the experiment background. We present a method to quantify the lowest trigger threshold achievable as a function of the acceptable amount of noise events triggered for the physics case under investigation. We then apply this novel method to existing experimental and simulated data to validate the model we presented.
Articolo in rivista - Articolo scientifico
Cryogenic detectors; Energy threshold; Rare event searches; Solid state detectors;
English
2019
940
1 October 2019
492
496
none
Mancuso, M., Bento, A., Ferreiro Iachellini, N., Hauff, D., Petricca, F., Probst, F., et al. (2019). A method to define the energy threshold depending on noise level for rare event searches. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 940(1 October 2019), 492-496 [10.1016/j.nima.2019.06.030].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/628778
Citazioni
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 14
Social impact