The development of a prosthetic hand able to replicate as much as possible the grasping and sensory features of the natural hand represents an ambitious project for scientists. State of the art technology is still far to provide engineers with components with similar performance of their natural models, and active prosthetic hands can be only a pale replication of the missing natural limb. This chapter presents the current research efforts towards the development of a self-adaptative and anthropomorphic prosthetic hand. In particular, the chapter is focused on the problem of replicating the natural sensory system of the hand with an artificial proprioceptive and exteroceptive sensory system.

Zecca, A., Cappiello, G., Sebastiani, F., Roccella, S., Vecchi, F., Carrozza, M., et al. (2004). Experimental analysis of the proprioceptive and exteroceptive sensors of an underactuated prosthetic hand. In 8th International Conference on Rehabilitation Robotics (ICORR 2003) (pp.233-242). SPRINGER-VERLAG BERLIN.

Experimental analysis of the proprioceptive and exteroceptive sensors of an underactuated prosthetic hand

Carrozza, MC;
2004

Abstract

The development of a prosthetic hand able to replicate as much as possible the grasping and sensory features of the natural hand represents an ambitious project for scientists. State of the art technology is still far to provide engineers with components with similar performance of their natural models, and active prosthetic hands can be only a pale replication of the missing natural limb. This chapter presents the current research efforts towards the development of a self-adaptative and anthropomorphic prosthetic hand. In particular, the chapter is focused on the problem of replicating the natural sensory system of the hand with an artificial proprioceptive and exteroceptive sensory system.
paper
Automation & Control Systems; Computer Science; Robotics; Rehabilitation
English
8th International Conference on Rehabilitation Robotics (ICORR 2003) - APR 22-25, 2003
2003
Bien, ZZ; Stefanov, D
8th International Conference on Rehabilitation Robotics (ICORR 2003)
3-540-21986-2
2004
306
233
242
none
Zecca, A., Cappiello, G., Sebastiani, F., Roccella, S., Vecchi, F., Carrozza, M., et al. (2004). Experimental analysis of the proprioceptive and exteroceptive sensors of an underactuated prosthetic hand. In 8th International Conference on Rehabilitation Robotics (ICORR 2003) (pp.233-242). SPRINGER-VERLAG BERLIN.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/623245
Citazioni
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 14
Social impact