Organic bioelectronic transistors emerged as powerful tools for probing cellular electrophysiology, offering biocompatibility, mechanical softness, and operational stability in biological environments. Despite these advantages, device benchmarking focused so far exclusively on electrical figures of merit, leaving interfacial processes that contribute to signal recording fidelity largely unexplored. Poly[2-(3,3′-bis(2-(2-(2-methoxyethoxy)ethoxy)ethoxy)-[2,2’-bithiophen]-5-yl)thieno[3,2-b]thiophene] (p(g2T-TT)) is a model glycolated organic mixed ionic-electronic conductor, whose high transconductance and optimal volumetric field-effect behavior in physiological environment have been widely documented in Organic Electrochemical Transistor (OECT) configurations. Thus, p(g2T-TT)-based OECT was assessed as a promising candidate for recording action potentials (APs) from human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs). Surprisingly, although AP signal transduction was observed, the recorded AP waveforms failed to reproduce the expected morphology, especially when compared to signals recorded via poly(3-hexylthiophene-2,5-diyl) (P3HT)-based Electrolyte-Gated Field-Effect Transistors (EGOFETs). Immunofluorescence imaging revealed improved adhesion on P3HT with respect to p(g2T-TT), suggesting weaker cell-device coupling as the underlying limitation. Our results show that not all polymers combining biocompatibility and high electrical performance can transduce AP signals with high-fidelity. Instead, interfacial properties govern bioelectronic transduction and provide a foundation for the rational design of polymers and platforms enabling reliable in vitro cellular electrophysiology, with potential translation to in vivo applications.

Zemignani, G., Mancinelli, E., Tullii, G., Khudiakov, A., Bortolotti, C., Tanwar, S., et al. (2026). Beyond Transconductance: Cell-Polymer Coupling Determines Fidelity in Action Potential Recording via Electrolyte-Gated Polymer Transistors. ADVANCED SCIENCE, 13(30) [10.1002/advs.202520122].

Beyond Transconductance: Cell-Polymer Coupling Determines Fidelity in Action Potential Recording via Electrolyte-Gated Polymer Transistors

Sala L.;
2026

Abstract

Organic bioelectronic transistors emerged as powerful tools for probing cellular electrophysiology, offering biocompatibility, mechanical softness, and operational stability in biological environments. Despite these advantages, device benchmarking focused so far exclusively on electrical figures of merit, leaving interfacial processes that contribute to signal recording fidelity largely unexplored. Poly[2-(3,3′-bis(2-(2-(2-methoxyethoxy)ethoxy)ethoxy)-[2,2’-bithiophen]-5-yl)thieno[3,2-b]thiophene] (p(g2T-TT)) is a model glycolated organic mixed ionic-electronic conductor, whose high transconductance and optimal volumetric field-effect behavior in physiological environment have been widely documented in Organic Electrochemical Transistor (OECT) configurations. Thus, p(g2T-TT)-based OECT was assessed as a promising candidate for recording action potentials (APs) from human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs). Surprisingly, although AP signal transduction was observed, the recorded AP waveforms failed to reproduce the expected morphology, especially when compared to signals recorded via poly(3-hexylthiophene-2,5-diyl) (P3HT)-based Electrolyte-Gated Field-Effect Transistors (EGOFETs). Immunofluorescence imaging revealed improved adhesion on P3HT with respect to p(g2T-TT), suggesting weaker cell-device coupling as the underlying limitation. Our results show that not all polymers combining biocompatibility and high electrical performance can transduce AP signals with high-fidelity. Instead, interfacial properties govern bioelectronic transduction and provide a foundation for the rational design of polymers and platforms enabling reliable in vitro cellular electrophysiology, with potential translation to in vivo applications.
Articolo in rivista - Articolo scientifico
cardiomyocytes action potentials; electrophysiology; organic bioelectronics; printed polymer transistor;
English
12-feb-2026
2026
13
30
e20122
open
Zemignani, G., Mancinelli, E., Tullii, G., Khudiakov, A., Bortolotti, C., Tanwar, S., et al. (2026). Beyond Transconductance: Cell-Polymer Coupling Determines Fidelity in Action Potential Recording via Electrolyte-Gated Polymer Transistors. ADVANCED SCIENCE, 13(30) [10.1002/advs.202520122].
File in questo prodotto:
File Dimensione Formato  
Zemignani et al-2026-Advanced Science-VoR.pdf

accesso aperto

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Licenza: Creative Commons
Dimensione 2.67 MB
Formato Adobe PDF
2.67 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/620141
Citazioni
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
Social impact