Introduction and hypothesis The aim of this study was to evaluate the functional outcome of a single-incision sling procedure for the treatment of female stress urinary incontinence (SUI) and to correlate the cure rate with a pelvic floor ultrasound examination Methods Fifty-seven patients treated with a single-incision sling procedure between January 2009 and September 2010 were included in the study. Functional outcome was evaluated as objective cure rate assessed with stress test and subjective cure rate determined by the International Consultation on Incontinence-Short Form and Patient Global Impression of Improvement scores. Women underwent perineal ultrasound examination by a combined 2D translabial and 3D transvaginal approach to assess bladder neck and tape mobility, tape position along the urethral axis, and tape anchorage. According to the position of self-fixating tips, we divided patients into group A (both tips crossed the obturator membrane), group B (only one tip crossed the obturatormembrane) and group C (none of the tips crossed the obturator membrane). Objective cure rate and type of anchorage were compared with all ultrasound parameters. Results At an average follow-up of 13 months objective cure rate was 87.7 % with a significant subjective improvement. A significant difference in tape mobility was noted between group A and group C. Bladder neck mobility significantly increased in failures. Sling was significantly closer to midurethra in cured than in failures. Conclusions In 77 % of patients MA didn't reach the obturator membrane on both sides. This feature conditioned significantly bladder neck mobility but not the efficacy of the procedure. Tape position seems to be the most important factor for success. © The International Urogynecological Association 2013.

Spelzini, F., Cesana, M., Verri, D., Polizzi, S., Frigerio, M., Milani, R. (2013). Three-dimensional ultrasound assessment and middle term efficacy of a single-incision sling. INTERNATIONAL UROGYNECOLOGY JOURNAL, 24(8), 1391-1397 [10.1007/s00192-012-2031-5].

Three-dimensional ultrasound assessment and middle term efficacy of a single-incision sling

SPELZINI, FEDERICO
Primo
;
CESANA, MARIA CRISTINA
Secondo
;
VERRI, DEBORA;POLIZZI, SERENA;FRIGERIO, MATTEO
Penultimo
;
MILANI, RODOLFO
Ultimo
2013

Abstract

Introduction and hypothesis The aim of this study was to evaluate the functional outcome of a single-incision sling procedure for the treatment of female stress urinary incontinence (SUI) and to correlate the cure rate with a pelvic floor ultrasound examination Methods Fifty-seven patients treated with a single-incision sling procedure between January 2009 and September 2010 were included in the study. Functional outcome was evaluated as objective cure rate assessed with stress test and subjective cure rate determined by the International Consultation on Incontinence-Short Form and Patient Global Impression of Improvement scores. Women underwent perineal ultrasound examination by a combined 2D translabial and 3D transvaginal approach to assess bladder neck and tape mobility, tape position along the urethral axis, and tape anchorage. According to the position of self-fixating tips, we divided patients into group A (both tips crossed the obturator membrane), group B (only one tip crossed the obturatormembrane) and group C (none of the tips crossed the obturator membrane). Objective cure rate and type of anchorage were compared with all ultrasound parameters. Results At an average follow-up of 13 months objective cure rate was 87.7 % with a significant subjective improvement. A significant difference in tape mobility was noted between group A and group C. Bladder neck mobility significantly increased in failures. Sling was significantly closer to midurethra in cured than in failures. Conclusions In 77 % of patients MA didn't reach the obturator membrane on both sides. This feature conditioned significantly bladder neck mobility but not the efficacy of the procedure. Tape position seems to be the most important factor for success. © The International Urogynecological Association 2013.
Articolo in rivista - Articolo scientifico
3D ultrasound; Incontinence surgery; Pelvic floor ultrasound; Single incision sling; Stress urinary incontinence; Suburethral sling; Adult; Aged; Endosonography; Female; Follow-Up Studies; Gynecologic Surgical Procedures; Humans; Middle Aged; Prospective Studies; Questionnaires; Treatment Outcome; Urinary Bladder; Urinary Incontinence, Stress; Urodynamics; Suburethral Slings; Urology; Obstetrics and Gynecology
English
2013
24
8
1391
1397
none
Spelzini, F., Cesana, M., Verri, D., Polizzi, S., Frigerio, M., Milani, R. (2013). Three-dimensional ultrasound assessment and middle term efficacy of a single-incision sling. INTERNATIONAL UROGYNECOLOGY JOURNAL, 24(8), 1391-1397 [10.1007/s00192-012-2031-5].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/61882
Citazioni
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 22
Social impact