Objective: Pathogenic or likely pathogenic copy-number variants (p/lpCNVs) are a significant cause of perinatal morbidity and mortality. Current prenatal screening based on cell-free DNA (cfDNA) fails to detect the majority of microimbalances (microdeletions/microduplications), leaving a significant residual risk of undetected chromosomal abnormalities. This study evaluated the clinical performance of a novel single-cell-sequencing-based non-invasive prenatal testing (scsbNIPT) method utilizing circulating extravillous trophoblasts (cEVTs) for the detection of fetal p/lpCNVs, particularly microimbalances < 8 Mb. Methods: This was a prospective, blinded, observational multicenter cohort study of 1390 high-risk pregnant women undergoing prenatal invasive diagnostic testing between November 2021 and December 2023. A 20-mL maternal blood sample was collected from each subject between 11 + 0 and 22 + 6 weeks' gestation prior to invasive sampling. cEVTs were isolated and subjected to whole-genome sequencing, using a proprietary workflow. scsbNIPT results were compared with standard invasive prenatal diagnostic results obtained by karyotyping and/or chromosomal microarray analysis. Results: scsbNIPT showed a sensitivity of 92.9% (95% CI, 76.5–99.1%) and a specificity of 98.2% (95% CI, 97.0–99.0%) for the detection of genome-wide microimbalances measuring ≥ 300 kb to < 8 Mb. The sensitivity for p/lpCNVs ≥ 300 kb in pregnancies screened at 11 + 0 to 14 + 6 weeks was 100% (95% CI, 83.9–100%). For trisomy 21, the sensitivity of scsbNIPT was 98.0% (95% CI, 92.9–99.8%) and the specificity was 99.7% (95% CI, 99.0–99.9%). Conclusions: This study demonstrates the scientific validity and clinical utility of scsbNIPT for the non-invasive detection of genome-wide fetal p/lpCNVs, particularly microimbalances, with high sensitivity and a resolution comparable to that of chromosomal microarray analysis. scsbNIPT may offer more complete screening for genome-wide p/lpCNVs, markedly lowering the residual risk early in pregnancy compared with existing cfDNA-based methods. © 2026 Menarini Silicon Biosystems. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
Stampalija, T., Forcato, C., Grati, F., Volpe, P., De Robertis, V., Izzi, C., et al. (2026). Single-cell-based non-invasive screening for fetal pathogenic microimbalances using maternal blood: comparison with invasive prenatal diagnosis. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 67(4), 500-509 [10.1002/uog.70201].
Single-cell-based non-invasive screening for fetal pathogenic microimbalances using maternal blood: comparison with invasive prenatal diagnosis
Ornaghi S.;
2026
Abstract
Objective: Pathogenic or likely pathogenic copy-number variants (p/lpCNVs) are a significant cause of perinatal morbidity and mortality. Current prenatal screening based on cell-free DNA (cfDNA) fails to detect the majority of microimbalances (microdeletions/microduplications), leaving a significant residual risk of undetected chromosomal abnormalities. This study evaluated the clinical performance of a novel single-cell-sequencing-based non-invasive prenatal testing (scsbNIPT) method utilizing circulating extravillous trophoblasts (cEVTs) for the detection of fetal p/lpCNVs, particularly microimbalances < 8 Mb. Methods: This was a prospective, blinded, observational multicenter cohort study of 1390 high-risk pregnant women undergoing prenatal invasive diagnostic testing between November 2021 and December 2023. A 20-mL maternal blood sample was collected from each subject between 11 + 0 and 22 + 6 weeks' gestation prior to invasive sampling. cEVTs were isolated and subjected to whole-genome sequencing, using a proprietary workflow. scsbNIPT results were compared with standard invasive prenatal diagnostic results obtained by karyotyping and/or chromosomal microarray analysis. Results: scsbNIPT showed a sensitivity of 92.9% (95% CI, 76.5–99.1%) and a specificity of 98.2% (95% CI, 97.0–99.0%) for the detection of genome-wide microimbalances measuring ≥ 300 kb to < 8 Mb. The sensitivity for p/lpCNVs ≥ 300 kb in pregnancies screened at 11 + 0 to 14 + 6 weeks was 100% (95% CI, 83.9–100%). For trisomy 21, the sensitivity of scsbNIPT was 98.0% (95% CI, 92.9–99.8%) and the specificity was 99.7% (95% CI, 99.0–99.9%). Conclusions: This study demonstrates the scientific validity and clinical utility of scsbNIPT for the non-invasive detection of genome-wide fetal p/lpCNVs, particularly microimbalances, with high sensitivity and a resolution comparable to that of chromosomal microarray analysis. scsbNIPT may offer more complete screening for genome-wide p/lpCNVs, markedly lowering the residual risk early in pregnancy compared with existing cfDNA-based methods. © 2026 Menarini Silicon Biosystems. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.| File | Dimensione | Formato | |
|---|---|---|---|
|
Stampalija et al-2026-Ultrasound in Obstetrics and Gynecology-VoR.pdf
accesso aperto
Tipologia di allegato:
Publisher’s Version (Version of Record, VoR)
Licenza:
Creative Commons
Dimensione
469.81 kB
Formato
Adobe PDF
|
469.81 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


