A 79-year-old man with heart failure was referred to our attention for a degenerated bio-Bentall Mitroflow 27. The Heart Team decided for a valve-in-valve (ViV) transcatheter aortic valve implantation with an Acurate neo M associated to coronary protection due to high risk of coronary obstruction (CO). Besides the supra-anular design, this case shows additional potential advantages of the Acurate neo in ViV procedures: the upper crown, which is meant to favor supra-anular anchoring, also let to cap the bioprosthesis leaflets and minimize the risk of CO; there is not any interference between the valve cage and the stents protruding into the aorta, avoiding potential stent crushing and assuming an easier future coronary engagement.

Laricchia, A., Mangieri, A., Gallo, F., Latib, A., Fisicaro, A., Conti, R., et al. (2020). Valve-in-Valve Transcatheter Aortic Valve Implantation With Acurate neo for a Degenerated bio-Bentall. CARDIOVASCULAR REVASCULARIZATION MEDICINE, 21(11), 18-20 [10.1016/j.carrev.2019.09.017].

Valve-in-Valve Transcatheter Aortic Valve Implantation With Acurate neo for a Degenerated bio-Bentall

Mantovani, L;
2020

Abstract

A 79-year-old man with heart failure was referred to our attention for a degenerated bio-Bentall Mitroflow 27. The Heart Team decided for a valve-in-valve (ViV) transcatheter aortic valve implantation with an Acurate neo M associated to coronary protection due to high risk of coronary obstruction (CO). Besides the supra-anular design, this case shows additional potential advantages of the Acurate neo in ViV procedures: the upper crown, which is meant to favor supra-anular anchoring, also let to cap the bioprosthesis leaflets and minimize the risk of CO; there is not any interference between the valve cage and the stents protruding into the aorta, avoiding potential stent crushing and assuming an easier future coronary engagement.
Articolo in rivista - Articolo scientifico
Coronary obstruction; Coronary protection; Transcatheter aortic valve implantation; Valve-in-valve;
English
2020
21
11
18
20
none
Laricchia, A., Mangieri, A., Gallo, F., Latib, A., Fisicaro, A., Conti, R., et al. (2020). Valve-in-Valve Transcatheter Aortic Valve Implantation With Acurate neo for a Degenerated bio-Bentall. CARDIOVASCULAR REVASCULARIZATION MEDICINE, 21(11), 18-20 [10.1016/j.carrev.2019.09.017].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/603285
Citazioni
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
Social impact