This work presents the experimental results of a wavelet transform denoising algorithm (WTDA) that improves the ionoacoustic signal-to-noise ratio (SNR) and proton range measurement precision. Ionoacoustic detectors exploit the ultrasound signal generated by pulsed proton beams in energy absorbers (water or the human body) to localize the energy deposition with sub-millimeter precision, with interesting applications in beam monitoring during oncological hadron therapy treatments. By improving SNR and measurement precision, the WTDA allows significant reduction of the extra dose necessary for beam characterization. To validate the WTDA’s performance, two scenarios are presented. First, the WTDA was applied to the ionoacoustic signals from a 20 MeV proton beam, where it allowed for increasing the SNR by 17 dB and improving measurement precision by a factor of two. Then, the WTDA was applied to the simulated signals from a 200 MeV clinical beam where, compared to state-of-the-art algorithms, it achieved a −80% dose reduction when achieving the same 30 μm precision and a six-fold precision improvement for the same 17 Gy dose deposition.

Vallicelli, E., Baschirotto, A., Stevenazzi, L., Tambaro, M., De Matteis, M. (2025). Proton Range Measurement Precision in Ionoacoustic Experiments with Wavelet-Based Denoising Algorithm †. SENSORS, 25(14) [10.3390/s25144247].

Proton Range Measurement Precision in Ionoacoustic Experiments with Wavelet-Based Denoising Algorithm †

Vallicelli E. A.;Baschirotto A.;Stevenazzi L.;Tambaro M.;De Matteis M.
2025

Abstract

This work presents the experimental results of a wavelet transform denoising algorithm (WTDA) that improves the ionoacoustic signal-to-noise ratio (SNR) and proton range measurement precision. Ionoacoustic detectors exploit the ultrasound signal generated by pulsed proton beams in energy absorbers (water or the human body) to localize the energy deposition with sub-millimeter precision, with interesting applications in beam monitoring during oncological hadron therapy treatments. By improving SNR and measurement precision, the WTDA allows significant reduction of the extra dose necessary for beam characterization. To validate the WTDA’s performance, two scenarios are presented. First, the WTDA was applied to the ionoacoustic signals from a 20 MeV proton beam, where it allowed for increasing the SNR by 17 dB and improving measurement precision by a factor of two. Then, the WTDA was applied to the simulated signals from a 200 MeV clinical beam where, compared to state-of-the-art algorithms, it achieved a −80% dose reduction when achieving the same 30 μm precision and a six-fold precision improvement for the same 17 Gy dose deposition.
Articolo in rivista - Articolo scientifico
circuits and systems for biomedical applications; radiation therapy; ultrasound sensors;
English
8-lug-2025
2025
25
14
4247
open
Vallicelli, E., Baschirotto, A., Stevenazzi, L., Tambaro, M., De Matteis, M. (2025). Proton Range Measurement Precision in Ionoacoustic Experiments with Wavelet-Based Denoising Algorithm †. SENSORS, 25(14) [10.3390/s25144247].
File in questo prodotto:
File Dimensione Formato  
Vallicelli et al-2025-Sensors-VoR.pdf

accesso aperto

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Licenza: Creative Commons
Dimensione 2.78 MB
Formato Adobe PDF
2.78 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/594443
Citazioni
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
Social impact