The CMS detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillation crystals coupled to SiPMs with TOFHIR2 ASICs for the front-end readout. A resolution of 30-60 ps for MIP signals at a rate of 2.5 Mhit/s per channel is expected along the HL-LHC lifetime. We present an overview of the TOFHIR2 requirements and design, simulation results and measurements with TOFHIR2 ASICs. The measurements of TOFHIR2 associated to sensor modules were performed in different test setups using internal test pulses or blue and UV laser pulses emulating the signals expected in the experiment. The measurements show a time resolution of 24 ps initially during Beginning of Operation (BoO) and 58 ps at End of Operation (EoO) conditions, matching well the BTL requirements. We also showed that the time resolution is stable up to the highest expected MIP rate. Extensive radiation tests were performed, both with x-rays and heavy ions, showing that TOFHIR2 is not affected by the radiation environment during the experiment lifetime.

Albuquerque, E., Araujo, M., Benaglia, A., Boletti, A., Bugalho, R., Coutinho, T., et al. (2024). TOFHIR2: the readout ASIC of the CMS barrel MIP Timing Detector. JOURNAL OF INSTRUMENTATION, 19(5) [10.1088/1748-0221/19/05/P05048].

TOFHIR2: the readout ASIC of the CMS barrel MIP Timing Detector

Benaglia A.;De Guio F.;Ghezzi A.;Lucchini M.;Malberti M.;Palluotto S.;Tabarelli de Fatis T.;
2024

Abstract

The CMS detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillation crystals coupled to SiPMs with TOFHIR2 ASICs for the front-end readout. A resolution of 30-60 ps for MIP signals at a rate of 2.5 Mhit/s per channel is expected along the HL-LHC lifetime. We present an overview of the TOFHIR2 requirements and design, simulation results and measurements with TOFHIR2 ASICs. The measurements of TOFHIR2 associated to sensor modules were performed in different test setups using internal test pulses or blue and UV laser pulses emulating the signals expected in the experiment. The measurements show a time resolution of 24 ps initially during Beginning of Operation (BoO) and 58 ps at End of Operation (EoO) conditions, matching well the BTL requirements. We also showed that the time resolution is stable up to the highest expected MIP rate. Extensive radiation tests were performed, both with x-rays and heavy ions, showing that TOFHIR2 is not affected by the radiation environment during the experiment lifetime.
Articolo in rivista - Articolo scientifico
Front-end electronics for detector readout; Radiation-hard electronics; Timing detectors; VLSI circuits;
English
20-mag-2024
2024
19
5
P05048
none
Albuquerque, E., Araujo, M., Benaglia, A., Boletti, A., Bugalho, R., Coutinho, T., et al. (2024). TOFHIR2: the readout ASIC of the CMS barrel MIP Timing Detector. JOURNAL OF INSTRUMENTATION, 19(5) [10.1088/1748-0221/19/05/P05048].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/572389
Citazioni
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 8
Social impact