Objective. Heterostructured scintillators offer a promising solution to balance the sensitivity and timing in TOF-PET detectors. These scintillators utilize alternating layers of materials with complementary properties to optimize performance. However, the layering compromises time resolution due to light transport issues. This study explores double-sided readout—enabling improved light collection and Depth-of-Interaction (DOI) information retrieval—to mitigate this effect and enhance the timing capabilities of heterostructures. Approach. The time resolution and DOI performances of 3 × 3 × 20 mm3 BGO&EJ232 heterostructures were assessed in a single and double-sided readout (SSR and DSR, respectively) configuration using high-frequency electronics. Main results. Selective analysis of photopeak events yielded a DOI resolution of 6.4 ± 0.04 mm. Notably, the Coincidence Time Resolution (CTR) improved from 262 ± 8 ps (SSR) to 174 ± 6 ps (DSR) when measured in coincidence with a fast reference detector. Additionally, symmetrical configuration of two identical heterostructures in coincidence was tested, yielding in DSR a CTR of 254 ± 8 ps for all photopeak events and 107 ± 5 ps for the fastest events. Significance. By using high-frequency double-sided readout, we could measure DOI resolution and improve the time resolution of heterostructures of up to 40%. The DOI information resulted intrinsically captured in the average between the timestamps of the two SiPMs, without requiring any further correction.
Pagano, F., Kratochwil, N., Lowis, C., Choong, W., Paganoni, M., Pizzichemi, M., et al. (2024). Enhancing timing performance of heterostructures with double-sided readout. PHYSICS IN MEDICINE AND BIOLOGY, 69(20) [10.1088/1361-6560/ad7fc8].
Enhancing timing performance of heterostructures with double-sided readout
Pagano F.;Paganoni M.;Pizzichemi M.;
2024
Abstract
Objective. Heterostructured scintillators offer a promising solution to balance the sensitivity and timing in TOF-PET detectors. These scintillators utilize alternating layers of materials with complementary properties to optimize performance. However, the layering compromises time resolution due to light transport issues. This study explores double-sided readout—enabling improved light collection and Depth-of-Interaction (DOI) information retrieval—to mitigate this effect and enhance the timing capabilities of heterostructures. Approach. The time resolution and DOI performances of 3 × 3 × 20 mm3 BGO&EJ232 heterostructures were assessed in a single and double-sided readout (SSR and DSR, respectively) configuration using high-frequency electronics. Main results. Selective analysis of photopeak events yielded a DOI resolution of 6.4 ± 0.04 mm. Notably, the Coincidence Time Resolution (CTR) improved from 262 ± 8 ps (SSR) to 174 ± 6 ps (DSR) when measured in coincidence with a fast reference detector. Additionally, symmetrical configuration of two identical heterostructures in coincidence was tested, yielding in DSR a CTR of 254 ± 8 ps for all photopeak events and 107 ± 5 ps for the fastest events. Significance. By using high-frequency double-sided readout, we could measure DOI resolution and improve the time resolution of heterostructures of up to 40%. The DOI information resulted intrinsically captured in the average between the timestamps of the two SiPMs, without requiring any further correction.File | Dimensione | Formato | |
---|---|---|---|
Pagano et al-2024-Physics in Medicine and Biology-voR.pdf
accesso aperto
Descrizione: Original content from this work may be used under the terms of the Creative Commons Attribution 4.0 license.
Tipologia di allegato:
Publisher’s Version (Version of Record, VoR)
Licenza:
Creative Commons
Dimensione
1.56 MB
Formato
Adobe PDF
|
1.56 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.