The grafting of galactose units onto poly(ε-caprolactone) (PCL) substrates by a wet chemistry two-step procedure is proposed. Even though a reduction of hardness from 0.58-0.31 GPa to 0.12-0.05 GPa is achieved, the chemical functionalization does not negatively affect the tensile modulus (332.2 ± 31.3 MPa and 328.5 ± 34.7 MPa for unmodified and surface-modified PCL, respectively) and strength (15.1 ± 1.3 MPa and 14.8 ± 1.5 MPa as assessed before and after the surface modification, respectively), as well as the mechanical behaviour evaluated through small punch test. XPS and enzyme-linked lectin assay (ELLA) demonstrate the presence, and also the correct exposition of the saccharidic epitope on PCL substrates. The introduction of carbohydrate moieties on the PCL surfaces clearly enhances the hydrophilicity of the substrate, as the water contact angle decreases from 82.1 ± 5.8° to 62.1 ± 4.2°. Furthermore, preliminary biological analysis shows human mesenchymal stem cell viability over time and an improvement of cell adhesion and spreading.

Russo, L., Russo, T., Battocchio, C., Taraballi, F., Gloria, A., D’Amora, U., et al. (2015). Galactose grafting on poly(ε-caprolactone) substrates for tissue engineering: A preliminary study. CARBOHYDRATE RESEARCH, 405, 39-46 [10.1016/j.carres.2014.07.027].

Galactose grafting on poly(ε-caprolactone) substrates for tissue engineering: A preliminary study

RUSSO, LAURA
Primo
;
TARABALLI, FRANCESCA;NICOTRA, FRANCESCO;CIPOLLA, LAURA FRANCESCA
2015

Abstract

The grafting of galactose units onto poly(ε-caprolactone) (PCL) substrates by a wet chemistry two-step procedure is proposed. Even though a reduction of hardness from 0.58-0.31 GPa to 0.12-0.05 GPa is achieved, the chemical functionalization does not negatively affect the tensile modulus (332.2 ± 31.3 MPa and 328.5 ± 34.7 MPa for unmodified and surface-modified PCL, respectively) and strength (15.1 ± 1.3 MPa and 14.8 ± 1.5 MPa as assessed before and after the surface modification, respectively), as well as the mechanical behaviour evaluated through small punch test. XPS and enzyme-linked lectin assay (ELLA) demonstrate the presence, and also the correct exposition of the saccharidic epitope on PCL substrates. The introduction of carbohydrate moieties on the PCL surfaces clearly enhances the hydrophilicity of the substrate, as the water contact angle decreases from 82.1 ± 5.8° to 62.1 ± 4.2°. Furthermore, preliminary biological analysis shows human mesenchymal stem cell viability over time and an improvement of cell adhesion and spreading.
Articolo in rivista - Articolo scientifico
Galactose, PCL
English
2015
405
39
46
partially_open
Russo, L., Russo, T., Battocchio, C., Taraballi, F., Gloria, A., D’Amora, U., et al. (2015). Galactose grafting on poly(ε-caprolactone) substrates for tissue engineering: A preliminary study. CARBOHYDRATE RESEARCH, 405, 39-46 [10.1016/j.carres.2014.07.027].
File in questo prodotto:
File Dimensione Formato  
Cipolla_2.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 1.48 MB
Formato Adobe PDF
1.48 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
submittedmanuscript.pdf

accesso aperto

Tipologia di allegato: Submitted Version (Pre-print)
Dimensione 1.56 MB
Formato Adobe PDF
1.56 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/55306
Citazioni
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 21
Social impact