Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA LE MODIFICHE in fondo alla pagina
Bicocca Open Archive
In spring 2012 CERN provided two weeks of a short bunch proton beam dedicated to the neutrino velocity measurement over a distance of 730 km. The OPERA neutrino experiment at the underground Gran Sasso Laboratory used an upgraded setup compared to the 2011 measurements, improving the measurement time accuracy. An independent timing system based on the Resistive Plate Chambers was exploited providing a time accuracy of similar to 1 ns. Neutrino and anti-neutrino contribution were separated using the information provided by the OPERA magnetic spectrometers. The new analysis profited from the precision geodesy measurements of the neutrino beaseline and of the CNGS/LNGS clock synchronization. The neutrino arrival time with respect to the one computed assuming the speed of light in vacuum is found to be delta t(nu) equivalent to TOFc - TOF nu = (0.6 +/- 0.4 (stat.)+/- 3.0 (syst.)) and delta t((nu) over bar) equivalent to TOFc-TOF(nu) over bar = (1.7 +/- 1.4 (stat.)+/- 3.1 (syst.)) ns for nu(mu) and (nu) over bar (mu), respectively. This corresponds to a limit on the muon neutrino velocity with respect to the speed of light of -1.8 x 10(-6) < (V-nu - c)/c < 2.3 x 10(-6) at 90% C.L. This new measurement confirms with higher accuracy the revised OPERA result
Adam, T., Agafonova, N., Aleksandrov, A., Anokhina, A., Aoki, S., Ariga, A., et al. (2013). Measurement of the neutrino velocity with the OPERA detector in the CNGS beam using the 2012 dedicated data. JOURNAL OF HIGH ENERGY PHYSICS, 2013(1) [10.1007/JHEP01(2013)153].
Measurement of the neutrino velocity with the OPERA detector in the CNGS beam using the 2012 dedicated data
In spring 2012 CERN provided two weeks of a short bunch proton beam dedicated to the neutrino velocity measurement over a distance of 730 km. The OPERA neutrino experiment at the underground Gran Sasso Laboratory used an upgraded setup compared to the 2011 measurements, improving the measurement time accuracy. An independent timing system based on the Resistive Plate Chambers was exploited providing a time accuracy of similar to 1 ns. Neutrino and anti-neutrino contribution were separated using the information provided by the OPERA magnetic spectrometers. The new analysis profited from the precision geodesy measurements of the neutrino beaseline and of the CNGS/LNGS clock synchronization. The neutrino arrival time with respect to the one computed assuming the speed of light in vacuum is found to be delta t(nu) equivalent to TOFc - TOF nu = (0.6 +/- 0.4 (stat.)+/- 3.0 (syst.)) and delta t((nu) over bar) equivalent to TOFc-TOF(nu) over bar = (1.7 +/- 1.4 (stat.)+/- 3.1 (syst.)) ns for nu(mu) and (nu) over bar (mu), respectively. This corresponds to a limit on the muon neutrino velocity with respect to the speed of light of -1.8 x 10(-6) < (V-nu - c)/c < 2.3 x 10(-6) at 90% C.L. This new measurement confirms with higher accuracy the revised OPERA result
Adam, T., Agafonova, N., Aleksandrov, A., Anokhina, A., Aoki, S., Ariga, A., et al. (2013). Measurement of the neutrino velocity with the OPERA detector in the CNGS beam using the 2012 dedicated data. JOURNAL OF HIGH ENERGY PHYSICS, 2013(1) [10.1007/JHEP01(2013)153].
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/53201
Citazioni
18
13
Social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 598/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.