CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of 130Te . We present the first data analysis with 7.1kg⋅y of total TeO2 exposure focusing on background measurements and energy resolution. The background rates in the neutrinoless double-beta decay region of interest (2.47 to 2.57MeV ) and in the α background-dominated region (2.70 to 3.90MeV ) have been measured to be 0.071±0.011 and 0.019±0.002counts/(keV⋅kg⋅y) , respectively. The latter result represents a factor of 6 improvement from a predecessor experiment, Cuoricino. The results verify our understanding of the background sources in CUORE-0, which is the basis of extrapolations to the full CUORE detector. The obtained energy resolution (full width at half maximum) in the region of interest is 5.7keV . Based on the measured background rate and energy resolution in the region of interest, CUORE-0 half-life sensitivity is expected to surpass the observed lower bound of Cuoricino with one year of live time.

Artusa, D., Avignone, F., Azzolini, O., Balata, M., Banks, T., Bari, G., et al. (2014). Initial performance of the CUORE-0 experiment. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS, 74(8), 1-7 [10.1140/epjc/s10052-014-2956-6].

Initial performance of the CUORE-0 experiment

BIASSONI, MATTEO;BROFFERIO, CHIARA;Canonica, L;CAPELLI, SILVIA;CHIESA, DAVIDE;CLEMENZA, MASSIMILIANO;Cremonesi, O;FAVERZANI, MARCO;FERRI, ELENA;FIORINI, ETTORE;GIACHERO, ANDREA;GIRONI, LUCA;GOTTI, CLAUDIO;NUCCIOTTI, ANGELO ENRICO LODOVICO;Pattavina, L;PAVAN, MAURA;Pessina, G;Previtali, E;SISTI, MONICA;TERRANOVA, FRANCESCO;ZANOTTI, LUIGI ERNESTO;
2014

Abstract

CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of 130Te . We present the first data analysis with 7.1kg⋅y of total TeO2 exposure focusing on background measurements and energy resolution. The background rates in the neutrinoless double-beta decay region of interest (2.47 to 2.57MeV ) and in the α background-dominated region (2.70 to 3.90MeV ) have been measured to be 0.071±0.011 and 0.019±0.002counts/(keV⋅kg⋅y) , respectively. The latter result represents a factor of 6 improvement from a predecessor experiment, Cuoricino. The results verify our understanding of the background sources in CUORE-0, which is the basis of extrapolations to the full CUORE detector. The obtained energy resolution (full width at half maximum) in the region of interest is 5.7keV . Based on the measured background rate and energy resolution in the region of interest, CUORE-0 half-life sensitivity is expected to surpass the observed lower bound of Cuoricino with one year of live time.
Articolo in rivista - Articolo scientifico
CUORE-0 experiment, neutrinoless double-beta decay, cryogenic detectors, tellurium dioxide bolometers, background analysis
English
2014
74
8
1
7
2956
reserved
Artusa, D., Avignone, F., Azzolini, O., Balata, M., Banks, T., Bari, G., et al. (2014). Initial performance of the CUORE-0 experiment. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS, 74(8), 1-7 [10.1140/epjc/s10052-014-2956-6].
File in questo prodotto:
File Dimensione Formato  
14EPJC-CUORE0.pdf

Solo gestori archivio

Dimensione 473.68 kB
Formato Adobe PDF
473.68 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/52903
Citazioni
  • Scopus 61
  • ???jsp.display-item.citation.isi??? 56
Social impact