Background: We hypothesized that a negative microvolt T-wave alternans (MTWA) test would identify patients unlikely to benefit from primary prevention implantable cardioverter defibrillator (ICD) therapy in a prospective cohort. Methods and Results: Data were pooled from 8 centers where MTWA testing was performed specifically for the purpose of guiding primary prevention ICD implantation. Cohorts were included if the ratio of ICDs implanted in patients who were MTWA "non-negative" to patients who were MTWA negative was >2:1, indicating that MTWA testing had a significant impact on the decision to implant an ICD. The pooled cohort included 651 patients: 371 MTWA non-negative and 280 MTWA negative. Among non-negative patients, 62% underwent ICD implantation whereas only 13% of MTWA-negative patients received an ICD (P<0.01). Despite a substantially lower prevalence of ICDs, long-term survival (6.9 years) was significantly better among MTWA-negative patients (68.2% non-negative vs. 87.1% negative, P=0.026). Conclusions: MTWA-negative patients had significantly better survival than MTWA non-negative patients, the majority of whom had ICDs. Despite a very low prevalence of ICDs, long-term survival among patients with left ventricular ejection fraction ≤40% and a negative MTWA test was better than in the ICD arm of any study to date that has demonstrated a benefit of ICDs. This provides further evidence that MTWA-negative patients are unlikely to benefit from primary prevention ICD therapy.
Merchant, F., Salerno-Uriarte, J., Caravati, F., Falcone, S., Molon, G., Marangoni, D., et al. (2015). Prospective use of microvolt T-wave alternans testing to guide primary prevention implantable cardioverter defibrillator therapy. CIRCULATION JOURNAL, 79(9), 1912-1919 [10.1253/circj.CJ-15-0253].
Prospective use of microvolt T-wave alternans testing to guide primary prevention implantable cardioverter defibrillator therapy
Pedretti R. F. E.;
2015
Abstract
Background: We hypothesized that a negative microvolt T-wave alternans (MTWA) test would identify patients unlikely to benefit from primary prevention implantable cardioverter defibrillator (ICD) therapy in a prospective cohort. Methods and Results: Data were pooled from 8 centers where MTWA testing was performed specifically for the purpose of guiding primary prevention ICD implantation. Cohorts were included if the ratio of ICDs implanted in patients who were MTWA "non-negative" to patients who were MTWA negative was >2:1, indicating that MTWA testing had a significant impact on the decision to implant an ICD. The pooled cohort included 651 patients: 371 MTWA non-negative and 280 MTWA negative. Among non-negative patients, 62% underwent ICD implantation whereas only 13% of MTWA-negative patients received an ICD (P<0.01). Despite a substantially lower prevalence of ICDs, long-term survival (6.9 years) was significantly better among MTWA-negative patients (68.2% non-negative vs. 87.1% negative, P=0.026). Conclusions: MTWA-negative patients had significantly better survival than MTWA non-negative patients, the majority of whom had ICDs. Despite a very low prevalence of ICDs, long-term survival among patients with left ventricular ejection fraction ≤40% and a negative MTWA test was better than in the ICD arm of any study to date that has demonstrated a benefit of ICDs. This provides further evidence that MTWA-negative patients are unlikely to benefit from primary prevention ICD therapy.File | Dimensione | Formato | |
---|---|---|---|
Merchant-2015-Circulation Journal-VoR.pdf
Solo gestori archivio
Tipologia di allegato:
Publisher’s Version (Version of Record, VoR)
Licenza:
Tutti i diritti riservati
Dimensione
953.95 kB
Formato
Adobe PDF
|
953.95 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.