Objective: To compare image quality of magnetic resonance arthrography (MRA) of the hip with intra-articular injection of high-viscosity hyaluronic acid (HA-MRA) versus Gd-based contrast agent (Gd-MRA) in patients with femoroacetabular impingement (FAI). Materials and methods: Design: single-centre, observational, retrospective, inter-individual, and cross-sectional. FAI patients who underwent HA-MRA (3 mL of high-viscosity HA plus 17 mL of saline) were compared with 37 age- and sex-matched FAI patients who underwent Gd-MRA (20 mL of 2 mmol/L solution of gadopentetate dimeglumine). Two independent blinded radiologists assessed image quality for all sequences (two-dimensional proton density, non-fat-sat axial, fat-sat coronal and sagittal; three-dimensional dual-echo steady state), using a 5-point Likert scale considering separately labrum, cartilage, round ligament, transverse ligament, and capsule. Pearson χ2 and Cohen κ were used. Results: The HA-MRA group was composed of 37 patients (23 males, 14 females; median age 38 years), the Gd-MRA group of 37 patients (21 males, 16 females; median age 38 years), without significant difference for age (p = 0.937) and sex (p = 0.636). Image quality did not differ between the two readers for any structure: labrum (p ≥ 0.340), cartilage (p ≥ 0.198), round ligament (p ≥ 0.255), transverse ligament (p ≥ 0.806), and capsule (p ≥ 0.314). Inter-reader agreement (κ) ranged from 0.785 to 1.000. Conclusions: HA-MRA provided an image quality not significantly different from that of Gd-MRA. This may open the possibility of combining MRA and viscosupplementation in one single procedure.

Randelli, F., Nocerino, E., Nicosia, L., Alì, M., Monti, C., Sardanelli, F., et al. (2020). Image quality of hip MR arthrography with intra-articular injection of hyaluronic acid versus gadolinium-based contrast agent in patients with femoroacetabular impingement. SKELETAL RADIOLOGY, 49(6), 937-944 [10.1007/s00256-019-03366-y].

Image quality of hip MR arthrography with intra-articular injection of hyaluronic acid versus gadolinium-based contrast agent in patients with femoroacetabular impingement

Aliprandi A
2020

Abstract

Objective: To compare image quality of magnetic resonance arthrography (MRA) of the hip with intra-articular injection of high-viscosity hyaluronic acid (HA-MRA) versus Gd-based contrast agent (Gd-MRA) in patients with femoroacetabular impingement (FAI). Materials and methods: Design: single-centre, observational, retrospective, inter-individual, and cross-sectional. FAI patients who underwent HA-MRA (3 mL of high-viscosity HA plus 17 mL of saline) were compared with 37 age- and sex-matched FAI patients who underwent Gd-MRA (20 mL of 2 mmol/L solution of gadopentetate dimeglumine). Two independent blinded radiologists assessed image quality for all sequences (two-dimensional proton density, non-fat-sat axial, fat-sat coronal and sagittal; three-dimensional dual-echo steady state), using a 5-point Likert scale considering separately labrum, cartilage, round ligament, transverse ligament, and capsule. Pearson χ2 and Cohen κ were used. Results: The HA-MRA group was composed of 37 patients (23 males, 14 females; median age 38 years), the Gd-MRA group of 37 patients (21 males, 16 females; median age 38 years), without significant difference for age (p = 0.937) and sex (p = 0.636). Image quality did not differ between the two readers for any structure: labrum (p ≥ 0.340), cartilage (p ≥ 0.198), round ligament (p ≥ 0.255), transverse ligament (p ≥ 0.806), and capsule (p ≥ 0.314). Inter-reader agreement (κ) ranged from 0.785 to 1.000. Conclusions: HA-MRA provided an image quality not significantly different from that of Gd-MRA. This may open the possibility of combining MRA and viscosupplementation in one single procedure.
Articolo in rivista - Articolo scientifico
(MeSH terms); Arthrography; Femoroacetabular impingement; Hip joint; Hyaluronic acid; Magnetic resonance imaging;
English
2020
49
6
937
944
reserved
Randelli, F., Nocerino, E., Nicosia, L., Alì, M., Monti, C., Sardanelli, F., et al. (2020). Image quality of hip MR arthrography with intra-articular injection of hyaluronic acid versus gadolinium-based contrast agent in patients with femoroacetabular impingement. SKELETAL RADIOLOGY, 49(6), 937-944 [10.1007/s00256-019-03366-y].
File in questo prodotto:
File Dimensione Formato  
Randelli-2020-Skeletal Radiology-VoR.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Licenza: Tutti i diritti riservati
Dimensione 680.37 kB
Formato Adobe PDF
680.37 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/523823
Citazioni
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
Social impact