The γ-ray spectroscopy is a promising method for diagnosing fast ions and confined α particles in a fusion plasma device. This application requires γ-ray detectors with high energy resolution (say a few percent for γ-ray energies in the range 1-5 MeV), high efficiency and high count rate capability, ideally up to a few MHz. Furthermore, the detector will have to withstand the high 14 MeV and 2.45 MeV neutron fluxes produced by the main fusion reactions between deuterium and tritium. Experimental results demonstrate that the requirements on energy resolution, efficiency and count rate can be met with a LaBr3(Ce) scintillator detector equipped with fast digital data acquisition. The measured response of the detector to 2.45 MeV neutrons is presented in this paper and discussed in terms of the interaction mechanism between neutrons and detector. © 2013 The Authors. Published by Elsevier B.V. All rights reserved.

Cazzaniga, C., Croci, G., Giacomelli, L., Grosso, G., Nocente, M., Tardocchi, M., et al. (2013). LaBr3 scintillator response to admixed neutron and gamma-ray fluxes. Intervento presentato a: 13th Vienna Conference on Instrumentation, Vienna [10.1016/j.nima.2013.05.055].

LaBr3 scintillator response to admixed neutron and gamma-ray fluxes

CAZZANIGA, CARLO;CROCI, GABRIELE;GIACOMELLI, LUCA CARLO;NOCENTE, MASSIMO;GORINI, GIUSEPPE;
2013

Abstract

The γ-ray spectroscopy is a promising method for diagnosing fast ions and confined α particles in a fusion plasma device. This application requires γ-ray detectors with high energy resolution (say a few percent for γ-ray energies in the range 1-5 MeV), high efficiency and high count rate capability, ideally up to a few MHz. Furthermore, the detector will have to withstand the high 14 MeV and 2.45 MeV neutron fluxes produced by the main fusion reactions between deuterium and tritium. Experimental results demonstrate that the requirements on energy resolution, efficiency and count rate can be met with a LaBr3(Ce) scintillator detector equipped with fast digital data acquisition. The measured response of the detector to 2.45 MeV neutrons is presented in this paper and discussed in terms of the interaction mechanism between neutrons and detector. © 2013 The Authors. Published by Elsevier B.V. All rights reserved.
poster + paper
LaBr3 scintillator, response function, fusion neutrons
English
13th Vienna Conference on Instrumentation
2013
2013
732
384
387
none
Cazzaniga, C., Croci, G., Giacomelli, L., Grosso, G., Nocente, M., Tardocchi, M., et al. (2013). LaBr3 scintillator response to admixed neutron and gamma-ray fluxes. Intervento presentato a: 13th Vienna Conference on Instrumentation, Vienna [10.1016/j.nima.2013.05.055].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/51016
Citazioni
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
Social impact