The recent classification of human herpesvirus 6 (HHV-6) A and B, previously considered as two variants of the same virus, as two distinct herpesvirus species, emphasizes the need to develop and standardize specific methods for their detection and quantitation for clinical use. The development of two highly sensitive calibrated real-time PCR to quantify HHV-6A and -6B variants in clinical specimen is described. Both assays displayed the same wide linear dynamic range from 100 to 106 copies of viral DNA in a single reaction and sensitivity of one copy/reaction. These systems allow for HHV-6A/B DNA load quantitation in different types of clinical specimens: blood or tissue cells when combined with the CCR5 assay; cell-free samples (plasma or other biological fluids) in combination with the calibrator technology. Due to the absence of cross-amplification and cross-hybridization, these methods detect minute amounts of one viral species even in the presence of a large excess of the other, allowing a specific quantitation of both viruses in the case of mixed infections. The new qPCR methods provide sensitive and specific tool for monitoring HHV-6A/B DNA load in clinical samples, facilitating the study of these viruses in human diseases

Cassina, G., Russo, D., De Battista, D., Broccolo, F., Lusso, P., Malnati, M. (2013). Calibrated real-time polymerase chain reaction for specific quantitation of HHV-6A and HHV-6B in clinical samples. JOURNAL OF VIROLOGICAL METHODS, 189(1), 172-179 [10.1016/j.jviromet.2013.01.018].

Calibrated real-time polymerase chain reaction for specific quantitation of HHV-6A and HHV-6B in clinical samples

Broccolo, F;
2013

Abstract

The recent classification of human herpesvirus 6 (HHV-6) A and B, previously considered as two variants of the same virus, as two distinct herpesvirus species, emphasizes the need to develop and standardize specific methods for their detection and quantitation for clinical use. The development of two highly sensitive calibrated real-time PCR to quantify HHV-6A and -6B variants in clinical specimen is described. Both assays displayed the same wide linear dynamic range from 100 to 106 copies of viral DNA in a single reaction and sensitivity of one copy/reaction. These systems allow for HHV-6A/B DNA load quantitation in different types of clinical specimens: blood or tissue cells when combined with the CCR5 assay; cell-free samples (plasma or other biological fluids) in combination with the calibrator technology. Due to the absence of cross-amplification and cross-hybridization, these methods detect minute amounts of one viral species even in the presence of a large excess of the other, allowing a specific quantitation of both viruses in the case of mixed infections. The new qPCR methods provide sensitive and specific tool for monitoring HHV-6A/B DNA load in clinical samples, facilitating the study of these viruses in human diseases
Articolo in rivista - Articolo scientifico
HHV-6A; HHV-6B; Real-time quantitative PCR; Calibrated PCR; DNA load; Clinical diagnosis
English
2013
189
1
172
179
none
Cassina, G., Russo, D., De Battista, D., Broccolo, F., Lusso, P., Malnati, M. (2013). Calibrated real-time polymerase chain reaction for specific quantitation of HHV-6A and HHV-6B in clinical samples. JOURNAL OF VIROLOGICAL METHODS, 189(1), 172-179 [10.1016/j.jviromet.2013.01.018].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/49526
Citazioni
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 21
Social impact