This paper presents a digital denoising stage for Proton Sound Detectors, that measures the range (the penetration depth) of clinical proton beams, by sensing the Time-of-Flight (ToF) of the weak acoustic signal emitted at the end of the beam penetration path. Such acoustic signal/pulse is initially fed to a low-noise analog front-end for digitalization and then to the Acoustic Denoising Digital Signal Processing (AcousticDenDSP) stage. The digital acoustic pulse has a noise bandwidth of 1 MHz and a much narrower acoustic bandwidth, centered on different fundamental frequencies (38.5 kHz (300 kHz) for 200 MeV (65 MeV) clinical beams). Thus, the AcousticDenDSP system exhibits 50 kHz/350 kHz programmable center frequency (to manage different beam energy scenarios), performs a stopband noise rejection of 80 dB/decease (4th -order) and minimize phase distortion providing a maximum Time-of- Flight error lower than 0.09% (of proton beam range). The system has been designed in 28 nm CMOS, occupies an area of 0.225 mm2 and has been fully characterized at a behavioral/electrical level (after stimulation by a real proton-induced acoustic pulse). The clock frequency is 100 MHz and the power consumption estimated is 16.9 m W, with a static power contribution of 0.075 mW.
Malanchini, M., Baschirotto, A., Di Meo, G., Tambaro, M., Vallicelli, E., De Matteis, M. (2024). 38.5-300 kHz-Fundamental-Frequency Tuning Range 16.9 mW-Power Digital Denoising System for Proton Sound Detectors in 28 nm CMOS. In 2024 19th Conference on Ph.D Research in Microelectronics and Electronics (PRIME). IEEE [10.1109/prime61930.2024.10559708].
38.5-300 kHz-Fundamental-Frequency Tuning Range 16.9 mW-Power Digital Denoising System for Proton Sound Detectors in 28 nm CMOS
Malanchini, Mirco
;Baschirotto, Andrea;Tambaro, Mattia;Vallicelli, Elia Arturo;De Matteis, Marcello
2024
Abstract
This paper presents a digital denoising stage for Proton Sound Detectors, that measures the range (the penetration depth) of clinical proton beams, by sensing the Time-of-Flight (ToF) of the weak acoustic signal emitted at the end of the beam penetration path. Such acoustic signal/pulse is initially fed to a low-noise analog front-end for digitalization and then to the Acoustic Denoising Digital Signal Processing (AcousticDenDSP) stage. The digital acoustic pulse has a noise bandwidth of 1 MHz and a much narrower acoustic bandwidth, centered on different fundamental frequencies (38.5 kHz (300 kHz) for 200 MeV (65 MeV) clinical beams). Thus, the AcousticDenDSP system exhibits 50 kHz/350 kHz programmable center frequency (to manage different beam energy scenarios), performs a stopband noise rejection of 80 dB/decease (4th -order) and minimize phase distortion providing a maximum Time-of- Flight error lower than 0.09% (of proton beam range). The system has been designed in 28 nm CMOS, occupies an area of 0.225 mm2 and has been fully characterized at a behavioral/electrical level (after stimulation by a real proton-induced acoustic pulse). The clock frequency is 100 MHz and the power consumption estimated is 16.9 m W, with a static power contribution of 0.075 mW.| File | Dimensione | Formato | |
|---|---|---|---|
|
Malanchini-2024-PRIME-VoR.pdf
Solo gestori archivio
Tipologia di allegato:
Publisher’s Version (Version of Record, VoR)
Licenza:
Tutti i diritti riservati
Dimensione
1.22 MB
Formato
Adobe PDF
|
1.22 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.