Objectives: Over the last years ultrasound has shown to be an important tool for evaluating lung involvement, including interstitial lung disease (ILD) a potentially severe systemic involvement in many rheumatic and musculoskeletal diseases (RMD). Despite the potential sensitivity of the technique the actual use is hampered by the lack of consensual definitions of elementary lesions to be assessed and of the scanning protocol to apply. Within the Outcome Measures in Rheumatology (OMERACT) Ultrasound Working Group we aimed at developing consensus-based definitions for ultrasound detected ILD findings in RMDs and assessing their reliability in dynamic images. Methods: Based on the results from a systematic literature review, several findings were identified for defining the presence of ILD by ultrasound (i.e., Am-lines, B-lines, pleural cysts and pleural line irregularity). Therefore, a Delphi survey was conducted among 23 experts in sonography to agree on which findings should be included and on their definitions. Subsequently, a web-reliability exercise was performed to test the reliability of the agreed definitions on video-clips, by using kappa statistics. Results: After three rounds of Delphi an agreement >75 % was obtained to include and define B-lines and pleural line irregularity as elementary lesions to assess. The reliability in the web-based exercise, consisting of 80 video-clips (30 for pleural line irregularity, 50 for B-lines), showed moderate inter-reader reliability for both B-lines (kappa = 0.51) and pleural line irregularity (kappa = 0.58), while intra-reader reliability was good for both B-lines (kappa = 0.72) and pleural line irregularity (kappa = 0.75). Conclusion: Consensus-based ultrasound definitions for B-lines and pleural line irregularity were obtained, with moderate to good reliability to detect these lesions using video-clips. The next step will be testing the reliability in patients with ILD linked to RMDs and to propose a consensual and standardized protocol to scan such patients.
Delle Sedie, A., Terslev, L., Bruyn, G., Cazenave, T., Chrysidis, S., Diaz, M., et al. (2024). Standardization of interstitial lung disease assessment by ultrasound: results from a Delphi process and web-reliability exercise by the OMERACT ultrasound working group. SEMINARS IN ARTHRITIS AND RHEUMATISM, 65(April 2024) [10.1016/j.semarthrit.2024.152406].
Standardization of interstitial lung disease assessment by ultrasound: results from a Delphi process and web-reliability exercise by the OMERACT ultrasound working group
Scire' C.;
2024
Abstract
Objectives: Over the last years ultrasound has shown to be an important tool for evaluating lung involvement, including interstitial lung disease (ILD) a potentially severe systemic involvement in many rheumatic and musculoskeletal diseases (RMD). Despite the potential sensitivity of the technique the actual use is hampered by the lack of consensual definitions of elementary lesions to be assessed and of the scanning protocol to apply. Within the Outcome Measures in Rheumatology (OMERACT) Ultrasound Working Group we aimed at developing consensus-based definitions for ultrasound detected ILD findings in RMDs and assessing their reliability in dynamic images. Methods: Based on the results from a systematic literature review, several findings were identified for defining the presence of ILD by ultrasound (i.e., Am-lines, B-lines, pleural cysts and pleural line irregularity). Therefore, a Delphi survey was conducted among 23 experts in sonography to agree on which findings should be included and on their definitions. Subsequently, a web-reliability exercise was performed to test the reliability of the agreed definitions on video-clips, by using kappa statistics. Results: After three rounds of Delphi an agreement >75 % was obtained to include and define B-lines and pleural line irregularity as elementary lesions to assess. The reliability in the web-based exercise, consisting of 80 video-clips (30 for pleural line irregularity, 50 for B-lines), showed moderate inter-reader reliability for both B-lines (kappa = 0.51) and pleural line irregularity (kappa = 0.58), while intra-reader reliability was good for both B-lines (kappa = 0.72) and pleural line irregularity (kappa = 0.75). Conclusion: Consensus-based ultrasound definitions for B-lines and pleural line irregularity were obtained, with moderate to good reliability to detect these lesions using video-clips. The next step will be testing the reliability in patients with ILD linked to RMDs and to propose a consensual and standardized protocol to scan such patients.File | Dimensione | Formato | |
---|---|---|---|
DelleSedie-2024-Semin Arthritis Rheum-VoR.pdf
Solo gestori archivio
Tipologia di allegato:
Publisher’s Version (Version of Record, VoR)
Licenza:
Tutti i diritti riservati
Dimensione
420.63 kB
Formato
Adobe PDF
|
420.63 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.