BACKGROUND: The precision and accuracy of mass spectrometry (MS) made it a fundamental tool in anti-doping analysis. High-resolution (HR) mass spectrometers significantly improved compound identification. This study systematically analyzes data from an athlete (Subject 1) who tested positive for meldonium and compares it with data from a healthy volunteer (Subject 2) to examine the correctness of the doping verdict. CASE PRESENTATION: The documentation related to Subject 1 was thoroughly processed and analyzed. A study involving a volunteer (Subject 2) replicated Subject 1 regimen and urine sample collection for data alignment with anti-doping results, with Subject 2 reporting not using meldonium. The anti-doping agency’s analysis of Subject 1 showed the presence of meldonium at a concentration close to the established cut-off level. However, a closer examination revealed that one specific ion, crucial for meldonium identification, was absent from the mass spectra. Analyzing Subject 2 data, using the same methodology, the absence of the specific ion was confirmed, even though the volunteer did not consume meldonium. The European directive and the method that was validated and cited by the anti-doping agency identified meldonium on at least four specific ions, whereas the anti-doping analysis used only three ions. This discrepancy compromises the specificity of meldonium identification. CONCLUSIONS: To enhance the analytical methodology, two strategic interventions are suggested: adjusting the meldonium cut-off value and expanding the analysis to include meldonium metabolites. By addressing these avenues, the precision of meldonium detection and doping verdicts can be improved. In conclusion, this study challenges the anti-doping agency’s verdict and prompts a reevaluation of meldonium detection methodologies in anti-doping measures.

Cristoni, S., Vitarelli, F., Spiti, S., Brambilla, M., Larini, M., Calabrone, L., et al. (2023). Unraveling the complexity of anti-doping analysis: reassessing meldonium detection and doping verdicts in a case study. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 27(24), 114-118 [10.26355/eurrev_202312_34695].

Unraveling the complexity of anti-doping analysis: reassessing meldonium detection and doping verdicts in a case study

Vitarelli F.;Spiti S.;Leoni V.
Ultimo
2023

Abstract

BACKGROUND: The precision and accuracy of mass spectrometry (MS) made it a fundamental tool in anti-doping analysis. High-resolution (HR) mass spectrometers significantly improved compound identification. This study systematically analyzes data from an athlete (Subject 1) who tested positive for meldonium and compares it with data from a healthy volunteer (Subject 2) to examine the correctness of the doping verdict. CASE PRESENTATION: The documentation related to Subject 1 was thoroughly processed and analyzed. A study involving a volunteer (Subject 2) replicated Subject 1 regimen and urine sample collection for data alignment with anti-doping results, with Subject 2 reporting not using meldonium. The anti-doping agency’s analysis of Subject 1 showed the presence of meldonium at a concentration close to the established cut-off level. However, a closer examination revealed that one specific ion, crucial for meldonium identification, was absent from the mass spectra. Analyzing Subject 2 data, using the same methodology, the absence of the specific ion was confirmed, even though the volunteer did not consume meldonium. The European directive and the method that was validated and cited by the anti-doping agency identified meldonium on at least four specific ions, whereas the anti-doping analysis used only three ions. This discrepancy compromises the specificity of meldonium identification. CONCLUSIONS: To enhance the analytical methodology, two strategic interventions are suggested: adjusting the meldonium cut-off value and expanding the analysis to include meldonium metabolites. By addressing these avenues, the precision of meldonium detection and doping verdicts can be improved. In conclusion, this study challenges the anti-doping agency’s verdict and prompts a reevaluation of meldonium detection methodologies in anti-doping measures.
Articolo in rivista - Articolo scientifico
Anti-doping analysis; Doping verdict; False positive; Mass spectrometry; Meldonium; SANIST;
English
18-dic-2023
2023
27
24
114
118
open
Cristoni, S., Vitarelli, F., Spiti, S., Brambilla, M., Larini, M., Calabrone, L., et al. (2023). Unraveling the complexity of anti-doping analysis: reassessing meldonium detection and doping verdicts in a case study. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 27(24), 114-118 [10.26355/eurrev_202312_34695].
File in questo prodotto:
File Dimensione Formato  
Cristoni-2023-European Review for Medical and Pharmacological Sciences-VoR.pdf

accesso aperto

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Licenza: Creative Commons
Dimensione 430.02 kB
Formato Adobe PDF
430.02 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/490619
Citazioni
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
Social impact