TeO2 crystals are used as bolometers in experiments searching for Double Beta Decay without emission of neutrinos. One of the most important issues in this extremely delicate kind of experiments is the characterization of the background. The knowledge of the response to a particles in the energy range where the signal is expected is therefore a must. In this paper we report the results on the response function of a TeO2 bolometer to α 's emitted by 147Sm dissolved in the crystal at the growth phase. A Quenching Factor of (1.0076 ± 0.0005) is found, independent of the temperature in the investigated range. The energy resolution on a peaks shows a standard calorimeter energy dependence: σ [keV] = (0.56±0.02) (0.010±0.002)√E[keV]. Signal pulse shape shows no difference between α and β/γ particles. © 2010 IOP Publishing Ltd and SISSA.

Bellini, F., Biassoni, M., Bucci, C., Casali, N., Dafinei, I., Ge, Z., et al. (2010). Response of a TeO2bolometer to α particles. JOURNAL OF INSTRUMENTATION, 5(12) [10.1088/1748-0221/5/12/P12005].

Response of a TeO2bolometer to α particles

BIASSONI, MATTEO;
2010

Abstract

TeO2 crystals are used as bolometers in experiments searching for Double Beta Decay without emission of neutrinos. One of the most important issues in this extremely delicate kind of experiments is the characterization of the background. The knowledge of the response to a particles in the energy range where the signal is expected is therefore a must. In this paper we report the results on the response function of a TeO2 bolometer to α 's emitted by 147Sm dissolved in the crystal at the growth phase. A Quenching Factor of (1.0076 ± 0.0005) is found, independent of the temperature in the investigated range. The energy resolution on a peaks shows a standard calorimeter energy dependence: σ [keV] = (0.56±0.02) (0.010±0.002)√E[keV]. Signal pulse shape shows no difference between α and β/γ particles. © 2010 IOP Publishing Ltd and SISSA.
Articolo in rivista - Articolo scientifico
Bolometers for dark matter research; Cryogenic detectors;
English
2010
5
12
P12005
none
Bellini, F., Biassoni, M., Bucci, C., Casali, N., Dafinei, I., Ge, Z., et al. (2010). Response of a TeO2bolometer to α particles. JOURNAL OF INSTRUMENTATION, 5(12) [10.1088/1748-0221/5/12/P12005].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/48196
Citazioni
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 13
Social impact