The CMS Detector will be upgraded for the High-Luminosity LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL, respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillating crystals coupled to SiPMs that are read out by TOFHIR2 ASICs in the front-end system. A resolution of 30 ps for MIP signals is expected at the beginning of HL-LHC operation degrading to 60 ps at the end of operation due to the SiPMs radiation damage. Relative to the first version of the front-end ASIC, TOFHIR2X implements improved circuitry for mitigation of the SiPM dark current noise as well as a new current mode discriminator. We present an overview of the TOFHIR2 requirements and design, simulation results and the first measurements with TOFHIR2X silicon samples coupled to LYSO/SiPM prototype sensors.

Niknejad, T., Albuquerque, E., Benaglia, A., Boletti, A., Bugalho, R., De Guio, F., et al. (2022). Results with the TOFHIR2X Revision of the Front-end ASIC of the CMS MTD Barrel Timing Layer. In 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference Record, NSS/MIC 2021 and 28th International Symposium on Room-Temperature Semiconductor Detectors, RTSD 2022. Institute of Electrical and Electronics Engineers Inc. [10.1109/NSS/MIC44867.2021.9875751].

Results with the TOFHIR2X Revision of the Front-end ASIC of the CMS MTD Barrel Timing Layer

Benaglia A.;De Guio F.;Ghezzi A.;Lucchini M.;Malberti M.;De Fatis T. T.;
2022

Abstract

The CMS Detector will be upgraded for the High-Luminosity LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL, respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillating crystals coupled to SiPMs that are read out by TOFHIR2 ASICs in the front-end system. A resolution of 30 ps for MIP signals is expected at the beginning of HL-LHC operation degrading to 60 ps at the end of operation due to the SiPMs radiation damage. Relative to the first version of the front-end ASIC, TOFHIR2X implements improved circuitry for mitigation of the SiPM dark current noise as well as a new current mode discriminator. We present an overview of the TOFHIR2 requirements and design, simulation results and the first measurements with TOFHIR2X silicon samples coupled to LYSO/SiPM prototype sensors.
paper
Charged particles; Medical imaging; Radiation damage; Silicon; Timing circuits
English
2021 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2021 - 16 October 2021 through 23 October 2021
2021
2021 IEEE Nuclear Science Symposium and Medical Imaging Conference Record, NSS/MIC 2021 and 28th International Symposium on Room-Temperature Semiconductor Detectors, RTSD 2022
9781665421133
2022
none
Niknejad, T., Albuquerque, E., Benaglia, A., Boletti, A., Bugalho, R., De Guio, F., et al. (2022). Results with the TOFHIR2X Revision of the Front-end ASIC of the CMS MTD Barrel Timing Layer. In 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference Record, NSS/MIC 2021 and 28th International Symposium on Room-Temperature Semiconductor Detectors, RTSD 2022. Institute of Electrical and Electronics Engineers Inc. [10.1109/NSS/MIC44867.2021.9875751].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/477686
Citazioni
  • Scopus 6
  • ???jsp.display-item.citation.isi??? ND
Social impact