The strategies for and the performance of the CMS silicon tracking system alignment during the 2015–2018 data-taking period of the LHC are described. The alignment procedures during and after data taking are explained. Alignment scenarios are also derived for use in the simulation of the detector response. Systematic effects, related to intrinsic symmetries of the alignment task or to external constraints, are discussed and illustrated for different scenarios.

Tumasyan, A., Adam, W., Andrejkovic, J., Bergauer, T., Chatterjee, S., Damanakis, K., et al. (2022). Strategies and performance of the CMS silicon tracker alignment during LHC Run 2. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 1037 [10.1016/j.nima.2022.166795].

Strategies and performance of the CMS silicon tracker alignment during LHC Run 2

Monti F.;Benaglia A.;Boldrini G.;Brivio F.;Cetorelli F.;De Guio F.;Dinardo M. E.;Ghezzi A.;Govoni P.;Guzzi L.;Lucchini M. T.;Malberti M.;Massironi A.;Moroni L.;Paganoni M.;Pinolini B. S.;Ragazzi S.;Tabarelli de Fatis T.;Zuolo D.;Ortona G.;Valsecchi D.;Gerosa R.;Fiorendi S.;
2022

Abstract

The strategies for and the performance of the CMS silicon tracking system alignment during the 2015–2018 data-taking period of the LHC are described. The alignment procedures during and after data taking are explained. Alignment scenarios are also derived for use in the simulation of the detector response. Systematic effects, related to intrinsic symmetries of the alignment task or to external constraints, are discussed and illustrated for different scenarios.
Articolo in rivista - Articolo scientifico
Alignment; CMS; Detector; HipPy; Legacy reprocessing; MillePede-II; Tracker;
English
28-apr-2022
2022
1037
166795
none
Tumasyan, A., Adam, W., Andrejkovic, J., Bergauer, T., Chatterjee, S., Damanakis, K., et al. (2022). Strategies and performance of the CMS silicon tracker alignment during LHC Run 2. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 1037 [10.1016/j.nima.2022.166795].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/477139
Citazioni
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 1
Social impact