The Compact Muon Solenoid collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1.1 cm2 are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.
Acar, B., Adamov, G., Adloff, C., Afanasiev, S., Akchurin, N., Akgun, B., et al. (2022). Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons. JOURNAL OF INSTRUMENTATION, 17(5) [10.1088/1748-0221/17/05/P05022].
Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons
Acar B.;Adamov G.;Adloff C.
;Afanasiev S.;Akchurin N.;Akgun B.;Khan F. A.;Alhusseini M.;Alison J.;Alpana A.;Altopp G.;Alyari M.;An S.;Anagul S.;Andreev I.;Aspell P.;Atakisi I. O.;Bach O.;Baden A.;Bakas G.;Bakshi A.;Bannerjee S.;Bargassa P.;Barney D.;Beaudette F.;Beaujean F.;Becheva E.;Becker A.;Behera P.;Belloni A.;Bergauer T.;Besancon M.;Bhattacharya S.;Bhowmik D.;Bilki B.;Bloch P.;Bodek A.;Bonanomi M.;Bonnemaison A.;Bonomally S.;Borg J.;Bouyjou F.;Bower N.;Braga D.;Brashear J.;Brondolin E.;Bryant P.;Buchot Perraguin A.;Bueghly J.;Burkle B.;Butler-Nalin A.;Bychkova O.;Callier S.;Calvet D.;Cao X.;Cappati A.;Caraway B.;Caregari S.;Cauchois A.;Ceard L.;Cekmecelioglu Y. C.;Cerci S.;Cerminara G.;Chadeeva M.;Charitonidis N.;Chatterjee R.;Chen Y. M.;Chen Z.;Cheng H. J.;Cheng K. Y.;Chernichenko S.;Cheung H.;Chien C. H.;Choudhury S.;Coko D.;Collura G.;Couderc F.;Danilov M.;Dannheim D.;Daoud W.;Dauncey P.;David A.;Davies G.;Davignon O.;Day E.;Debarbaro P.;De Guio F.;De La Taille C.;De Silva M.;Debbins P.;Defranchis M. M.;Delagnes E.;Deltoro Berrio J. M.;Derylo G.;Dias De Almeida P. G.;Diaz D.;Dinaucourt P.;Dittmann J.;Dragicevic M.;Dugad S.;Dulucq F.;Dumanoglu I.;Dutta V.;Dutta S.;Dunser M.;Eckdahl J.;Edberg T. K.;El Berni M.;Elias F.;Eno S. C.;Ershov Y.;Everaerts P.;Extier S.;Fahim F.;Fallon C.;Fedi G.;Fontana Santos Alves B. A.;Frahm E.;Franzoni G.;Freeman J.;French T.;Gandhi P.;Ganjour S.;Gao X.;Garcia-Bellido A.;Gastaldi F.;Gecse Z.;Geerebaert Y.;Gerwig H.;Gevin O.;Ghosh S.;Gilbert A.;Gilbert W.;Gill K.;Gingu C.;Gninenko S.;Golunov A.;Golutvin I.;Gonzalez T.;Gorbounov N.;Gouskos L.;Gray A. B.;Gu Y.;Guilloux F.;Guler Y.;Gulmez E.;Guo J.;Gurpinar Guler E.;Hammer M.;Hassanshahi H. M.;Hatakeyama K.;Heering A.;Hegde V.;Heintz U.;Hinton N.;Hirschauer J.;Hoff J.;Hou W. -S.;Hou X.;Hua H.;Incandela J.;Irshad A.;Isik C.;Jain S.;Jheng H. R.;Joshi U.;Kachanov V.;Kalinin A.;Kalipoliti L.;Kaminskiy A.;Kapoor A.;Kara O.;Karneyeu A.;Kaya M.;Kaya O.;Kayis Topaksu A.;Khukhunaishvili A.;Kiesler J.;Kilpatrick M.;Kim S.;Koetz K.;Kolberg T.;Koseyan O. K.;Kristic A.;Krohn M.;Kruger K.;Kulagin N.;Kulis S.;Kunori S.;Kuo C. M.;Kuryatkov V.;Kyre S.;Lai Y.;Lamichhane K.;Landsberg G.;Lange C.;Langford J.;Lee M. Y.;Levin A.;Li A.;Li B.;Li J. H.;Li Y. Y.;Liao H.;Lincoln D.;Linssen L.;Lipton R.;Liu Y.;Lobanov A.;Lu R. -S.;Lupi M.;Lysova I.;Magnan A. -M.;Magniette F.;Mahjoub A.;Maier A. A.;Malakhov A.;Mallios S.;Mandjavize I.;Mannelli M.;Mans J.;Marchioro A.;Martelli A.;Martinez G.;Masterson P.;Meng B.;Mengke T.;Mestvirishvili A.;Mirza I.;Moccia S.;Mohanty G. B.;Monti F.;Morrissey I.;Murthy S.;Music J.;Musienko Y.;Nabili S.;Nagar A.;Nguyen M.;Nikitenko A.;Noonan D.;Noy M.;Nurdan K.;Ochando C.;Odegard B.;Odell N.;Okawa H.;Onel Y.;Ortez W.;Ozegovic J.;Ozkorucuklu S.;Paganis E.;Pagenkopf D.;Palladino V.;Pandey S.;Pantaleo F.;Papageorgakis C.;Papakrivopoulos I.;Parshook J.;Pastika N.;Paulini M.;Paulitsch P.;Peltola T.;Pereira Gomes R.;Perkins H.;Petiot P.;Pierre-Emile T.;Pitters F.;Popova E.;Prosper H.;Prvan M.;Puljak I.;Qu H.;Quast T.;Quinn R.;Quinnan M.;Ramos Garcia M. T.;Rao K. K.;Rapacz K.;Raux L.;Reichenbach G.;Reinecke M.;Revering M.;Roberts A.;Romanteau T.;Rose A.;Rovere M.;Roy A.;Rubinov P.;Rusack R.;Rusinov V.;Ryjov V.;Sahin O. M.;Salerno R.;Sanchez Rodriguez A. M.;Saradhy R.;Sarkar T.;Sarkisla M. A.;Sauvan J. B.;Schmidt I.;Schmitt M.;Scott E.;Seez C.;Sefkow F.;Sharma S.;Shein I.;Shenai A.;Shukla R.;Sicking E.;Sieberer P.;Silva P.;Simsek A. E.;Sirois Y.;Smirnov V.;Sozbilir U.;Spencer E.;Steen A.;Strait J.;Strobbe N.;Su J. W.;Sukhov E.;Sun L.;Sunar Cerci D.;Syal C.;Tali B.;Tan C. L.;Tao J.;Tastan I.;Tatli T.;Thaus R.;Tekten S.;Thienpont D.;Tiras E.;Titov M.;Tlisov D.;Tok U. G.;Troska J.;Tsai L. -S.;Tsamalaidze Z.;Tsipolitis G.;Tsirou A.;Tyurin N.;Undleeb S.;Urbanski D.;Ustinov V.;Uzunian A.;Van De Klundert M.;Varela J.;Velasco M.;Viazlo O.;Barreto Pinto M. V.;Vichoudis P.;Virdee T.;Vizinho De Oliveira R.;Voelker J.;Voirin E.;Vojinovic M.;Wade A.;Wang C.;Wang F.;Wang X.;Wang Z.;Wang Z.;Wayne M.;Webb S. N.;Whitbeck A.;White D.;Wickwire R.;Wilson J. S.;Winter D.;Wu H. Y.;Wu L.;Wulansatiti Nursanto M.;Yeh C. H.;Yohay R.;Yu D.;Yu G. B.;Yu S. S.;Yuan C.;Yumiceva F.;Yusuff I.;Zacharopoulou A.;Zamiatin N.;Zarubin A.;Zenz S.;Zghiche A.;Zhang H.;Zhang J.;Zhang Y.;Zhang Z.
2022
Abstract
The Compact Muon Solenoid collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1.1 cm2 are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/471938
Citazioni
7
5
Social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 598/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.