An on-chip solution for health monitoring of semiconductor power switches subjected to thermo-mechanical metal fatigue degradation is proposed. The fatigue detection relies on the correlation between the progress of the main failure mechanism, which is critical to the functionality of the device, and a parallel degradation of a non-critical sensing structure using a different mechanism. Both mechanisms are driven by the same cyclic thermo-mechanical load. This study specifically develops a sensing structure for detecting power metallization aging through electrically detectable ratcheting behavior in the routing metal layer underneath. Experiments have been carried out on a dedicated test structure with electrical sensing of the health monitoring structure. Meanwhile, the main degradation progress was observed via scanning electron microscopy in regular intervals. Results show that the proposed approach will reliably work only for detecting degradation driven by repeated high overload events.

De Gasperi, S., Nelhiebel, M., Haerle, D., Baschirotto, A. (2022). Power metallization degradation monitoring on power MOSFETs by means of concurrent degradation processes. JOURNAL OF POWER ELECTRONICS, 22(9), 1587-1595 [10.1007/s43236-022-00463-5].

Power metallization degradation monitoring on power MOSFETs by means of concurrent degradation processes

Baschirotto A.
2022

Abstract

An on-chip solution for health monitoring of semiconductor power switches subjected to thermo-mechanical metal fatigue degradation is proposed. The fatigue detection relies on the correlation between the progress of the main failure mechanism, which is critical to the functionality of the device, and a parallel degradation of a non-critical sensing structure using a different mechanism. Both mechanisms are driven by the same cyclic thermo-mechanical load. This study specifically develops a sensing structure for detecting power metallization aging through electrically detectable ratcheting behavior in the routing metal layer underneath. Experiments have been carried out on a dedicated test structure with electrical sensing of the health monitoring structure. Meanwhile, the main degradation progress was observed via scanning electron microscopy in regular intervals. Results show that the proposed approach will reliably work only for detecting degradation driven by repeated high overload events.
Articolo in rivista - Articolo scientifico
Degradation; Metallization; Monitoring; Power;
English
30-mag-2022
2022
22
9
1587
1595
none
De Gasperi, S., Nelhiebel, M., Haerle, D., Baschirotto, A. (2022). Power metallization degradation monitoring on power MOSFETs by means of concurrent degradation processes. JOURNAL OF POWER ELECTRONICS, 22(9), 1587-1595 [10.1007/s43236-022-00463-5].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/471630
Citazioni
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
Social impact