In this Letter, we present the design and performance of the frequency-dependent squeezed vacuum source that will be used for the broadband quantum noise reduction of the Advanced Virgo Plus gravitational-wave detector in the upcoming observation run. The frequency-dependent squeezed field is generated by a phase rotation of a frequency-independent squeezed state through a 285 m long, high-finesse, near-detuned optical resonator. With about 8.5 dB of generated squeezing, up to 5.6 dB of quantum noise suppression has been measured at high frequency while close to the filter cavity resonance frequency, the intracavity losses limit this value to about 2 dB. Frequency-dependent squeezing is produced with a rotation frequency stability of about 6 Hz rms, which is maintained over the long term. The achieved results fulfill the frequency dependent squeezed vacuum source requirements for Advanced Virgo Plus. With the current squeezing source, considering also the estimated squeezing degradation induced by the interferometer, we expect a reduction of the quantum shot noise and radiation pressure noise of up to 4.5 dB and 2 dB, respectively.

Acernese, F., Agathos, M., Ain, A., Albanesi, S., Allene, C., Allocca, A., et al. (2023). Frequency-Dependent Squeezed Vacuum Source for the Advanced Virgo Gravitational-Wave Detector. PHYSICAL REVIEW LETTERS, 131(4) [10.1103/PhysRevLett.131.041403].

Frequency-Dependent Squeezed Vacuum Source for the Advanced Virgo Gravitational-Wave Detector

Buscicchio R.;Carpinelli M.;Colombo A.;Colpi M.;Rozza D.;Salafia O. S.;
2023

Abstract

In this Letter, we present the design and performance of the frequency-dependent squeezed vacuum source that will be used for the broadband quantum noise reduction of the Advanced Virgo Plus gravitational-wave detector in the upcoming observation run. The frequency-dependent squeezed field is generated by a phase rotation of a frequency-independent squeezed state through a 285 m long, high-finesse, near-detuned optical resonator. With about 8.5 dB of generated squeezing, up to 5.6 dB of quantum noise suppression has been measured at high frequency while close to the filter cavity resonance frequency, the intracavity losses limit this value to about 2 dB. Frequency-dependent squeezing is produced with a rotation frequency stability of about 6 Hz rms, which is maintained over the long term. The achieved results fulfill the frequency dependent squeezed vacuum source requirements for Advanced Virgo Plus. With the current squeezing source, considering also the estimated squeezing degradation induced by the interferometer, we expect a reduction of the quantum shot noise and radiation pressure noise of up to 4.5 dB and 2 dB, respectively.
Articolo in rivista - Articolo scientifico
Gravitational effects; Gravity waves; Noise abatement; Quantum noise; Quantum optics; Signal detection
English
2023
131
4
041403
none
Acernese, F., Agathos, M., Ain, A., Albanesi, S., Allene, C., Allocca, A., et al. (2023). Frequency-Dependent Squeezed Vacuum Source for the Advanced Virgo Gravitational-Wave Detector. PHYSICAL REVIEW LETTERS, 131(4) [10.1103/PhysRevLett.131.041403].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/471458
Citazioni
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 12
Social impact