In the context of improving the detector performance of time-of-flight positron emission tomography (TOF-PET), the combination of charge induction readout and prompt Cherenkov photon production in semiconductor materials can lead to an outstanding detector performance in energy, timing, and spatial resolution. Energy resolutions as good as 1.2% at 662 keV and 5% at 122 keV are reported for pixel thallium bromide (TlBr) detectors. The high refractive index of Tl-based materials, between 2.3 and 2.6, leads to a high Cherenkov photon generation yield but can also challenge photon extraction, potentially affecting the time performance. In this work, the timing properties of TlBr and thallium chloride (TlCl) crystals of different geometries are measured using an optimized test setup with high-frequency readout electronics. A coincidence time resolution (CTR) value of 167 ± 6 ps FWHM is achieved using a 3 × 3 × 3 mm3 black-painted TlBr crystal. In order to assess potential improvements, a Geant4-based simulation tool kit is developed and validated against experimental measurements. The simulation tool kit is used to predict the contributions limiting the time resolution regarding the crystal and photodetector properties, highlighting the potential of such materials. Finally, paths to further improve the detector performance in TOF-PET are discussed.

Terragni, G., Pizzichemi, M., Roncali, E., Cherry, S., Glodo, J., Shah, K., et al. (2022). Time Resolution Studies of Thallium Based Cherenkov Semiconductors. FRONTIERS IN PHYSICS, 10 [10.3389/fphy.2022.785627].

Time Resolution Studies of Thallium Based Cherenkov Semiconductors

Pizzichemi M.;Ghezzi A.;
2022

Abstract

In the context of improving the detector performance of time-of-flight positron emission tomography (TOF-PET), the combination of charge induction readout and prompt Cherenkov photon production in semiconductor materials can lead to an outstanding detector performance in energy, timing, and spatial resolution. Energy resolutions as good as 1.2% at 662 keV and 5% at 122 keV are reported for pixel thallium bromide (TlBr) detectors. The high refractive index of Tl-based materials, between 2.3 and 2.6, leads to a high Cherenkov photon generation yield but can also challenge photon extraction, potentially affecting the time performance. In this work, the timing properties of TlBr and thallium chloride (TlCl) crystals of different geometries are measured using an optimized test setup with high-frequency readout electronics. A coincidence time resolution (CTR) value of 167 ± 6 ps FWHM is achieved using a 3 × 3 × 3 mm3 black-painted TlBr crystal. In order to assess potential improvements, a Geant4-based simulation tool kit is developed and validated against experimental measurements. The simulation tool kit is used to predict the contributions limiting the time resolution regarding the crystal and photodetector properties, highlighting the potential of such materials. Finally, paths to further improve the detector performance in TOF-PET are discussed.
Articolo in rivista - Articolo scientifico
Cherenkov emission; coincidence time resolution (CTR); GEANT4 simulation; silicon photomultiplier (SiPM); TlBr crystal; TlCl crystal; TOF-PET;
English
2022
10
785627
none
Terragni, G., Pizzichemi, M., Roncali, E., Cherry, S., Glodo, J., Shah, K., et al. (2022). Time Resolution Studies of Thallium Based Cherenkov Semiconductors. FRONTIERS IN PHYSICS, 10 [10.3389/fphy.2022.785627].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/445822
Citazioni
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 11
Social impact