Aims: We aimed to estimate the rate of renal artery adverse events following renal denervation with the most commonly applied radiofrequency catheter system based on a comprehensive review of published reports. Methods and results: We reviewed 50 published renal denervation (RDN) trials reporting on procedural safety including 5,769 subjects with 10,249 patient-years of follow-up. Twenty-six patients with renal artery stenosis or dissection (0.45%) were identified of whom 24 (0.41%) required renal artery stenting. The primary meta-analysis of all reports indicated a 0.20% pooled annual incidence rate of stent implantation (95% CI: 0.12 to 0.29% per year). Additional sensitivity analyses yielded consistent pooled estimates (range: 0.17 to 0.42% per year). Median time from RDN procedure to all renal intervention was 5.5 months (range: 0 to 33 months); 79% of all events occurred within one year of the procedure. A separate review of 14 clinical trials reporting on prospective follow-up imaging using either magnetic resonance imaging, computed tomography or angiography following RDN in 511 total subjects identified just 1 new significant stenosis (0.20%) after a median of 11 months post procedure (one to 36 months). Conclusions: Renal artery reintervention following renal denervation with the most commonly applied RF renal denervation system (Symplicity) is rare. Most events were identified within one year.

Townsend, R., Walton, A., Hettrick, D., Hickey, G., Weil, J., Sharp, A., et al. (2021). Review and meta-analysis of renal artery damage following percutaneous renal denervation with radiofrequency renal artery ablation. EUROINTERVENTION, 16(1), 89-96 [10.4244/eij-d-19-00902].

Review and meta-analysis of renal artery damage following percutaneous renal denervation with radiofrequency renal artery ablation

Mancia G.
2021

Abstract

Aims: We aimed to estimate the rate of renal artery adverse events following renal denervation with the most commonly applied radiofrequency catheter system based on a comprehensive review of published reports. Methods and results: We reviewed 50 published renal denervation (RDN) trials reporting on procedural safety including 5,769 subjects with 10,249 patient-years of follow-up. Twenty-six patients with renal artery stenosis or dissection (0.45%) were identified of whom 24 (0.41%) required renal artery stenting. The primary meta-analysis of all reports indicated a 0.20% pooled annual incidence rate of stent implantation (95% CI: 0.12 to 0.29% per year). Additional sensitivity analyses yielded consistent pooled estimates (range: 0.17 to 0.42% per year). Median time from RDN procedure to all renal intervention was 5.5 months (range: 0 to 33 months); 79% of all events occurred within one year of the procedure. A separate review of 14 clinical trials reporting on prospective follow-up imaging using either magnetic resonance imaging, computed tomography or angiography following RDN in 511 total subjects identified just 1 new significant stenosis (0.20%) after a median of 11 months post procedure (one to 36 months). Conclusions: Renal artery reintervention following renal denervation with the most commonly applied RF renal denervation system (Symplicity) is rare. Most events were identified within one year.
Articolo in rivista - Review Essay
Clinical research; Renal sympathetic denervation; Uncontrolled hypertension;
English
2021
16
1
89
96
none
Townsend, R., Walton, A., Hettrick, D., Hickey, G., Weil, J., Sharp, A., et al. (2021). Review and meta-analysis of renal artery damage following percutaneous renal denervation with radiofrequency renal artery ablation. EUROINTERVENTION, 16(1), 89-96 [10.4244/eij-d-19-00902].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/433269
Citazioni
  • Scopus 76
  • ???jsp.display-item.citation.isi??? 76
Social impact