Compact X-rays detectors made of 1/2” or 1”: LaBr3:Ce crystals of cubic shape with SiPM array readout have been developed for the FAMU experiment at RIKEN-RAL. The aim is a precise measurement of the proton Zemach radius with incoming muons. Additional applications may be found in medical physics, such as PET, homeland security and gamma-ray astronomy. Due to the high photon yield of LaBr3:Ce it was possible to use a simple readout scheme based on CAEN V1730 digitizers. Detectors, using Hamamatsu S13361 or S14161 arrays, have good FWHM energy resolutions up to 3% (8%) at the Cs137 (Co57) peak, comparing well with the best results obtained with a photomultiplier's readout. Detailed studies were performed to correct online the drift with temperature of SiPM gain and to reduce the risetime/falltime of detectors’ signals, that increased going from 1/2” to 1” detectors, due to the larger capacity of the used SiPM arrays.
Bonesini, M., Benocci, R., Bertoni, R., Menegolli, A., Prata, M., Rossella, M., et al. (2023). Large area LaBr3:Ce crystals read by SiPM arrays with improved timing and temperature gain drift control. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 1046(11 January 2023) [10.1016/j.nima.2022.167677].
Large area LaBr3:Ce crystals read by SiPM arrays with improved timing and temperature gain drift control
Benocci R.;
2023
Abstract
Compact X-rays detectors made of 1/2” or 1”: LaBr3:Ce crystals of cubic shape with SiPM array readout have been developed for the FAMU experiment at RIKEN-RAL. The aim is a precise measurement of the proton Zemach radius with incoming muons. Additional applications may be found in medical physics, such as PET, homeland security and gamma-ray astronomy. Due to the high photon yield of LaBr3:Ce it was possible to use a simple readout scheme based on CAEN V1730 digitizers. Detectors, using Hamamatsu S13361 or S14161 arrays, have good FWHM energy resolutions up to 3% (8%) at the Cs137 (Co57) peak, comparing well with the best results obtained with a photomultiplier's readout. Detailed studies were performed to correct online the drift with temperature of SiPM gain and to reduce the risetime/falltime of detectors’ signals, that increased going from 1/2” to 1” detectors, due to the larger capacity of the used SiPM arrays.File | Dimensione | Formato | |
---|---|---|---|
Bonesini-2023-NIM A-VoR.pdf
Solo gestori archivio
Descrizione: Research Article
Tipologia di allegato:
Publisher’s Version (Version of Record, VoR)
Licenza:
Tutti i diritti riservati
Dimensione
1.18 MB
Formato
Adobe PDF
|
1.18 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.