Purpose: There is no consensus yet on the best protocol for planar image acquisition and interpretation of radiolabelled white blood cell (WBC) scintigraphy. This may account for differences in reported diagnostic accuracy amongst different centres. Methods: This was a multicentre retrospective study analysing 235 WBC scans divided into two groups. The first group of scans (105 patients) were acquired with a fixed-time acquisition protocol and the second group (130 patients) were acquired with a decay time-corrected acquisition protocol. Planar images were interpreted both qualitatively and semiquantitatively. Three blinded readers analysed the images. Results: The most accurate imaging acquisition protocol comprised image acquisition at 3 - 4 h and at 20 - 24 h in time mode with acquisition times corrected for isotope decay. Conclusion: Using this protocol, visual analysis had high sensitivity and specificity in the diagnosis of infection. Semiquantitative analysis could be used in doubtful cases, with no cut-off for the percentage increase in radiolabelled WBC over time, as a criterion to define a positive scan.

Erba, P., Glaudemans, A., Veltman, N., Sollini, M., Pacilio, M., Galli, F., et al. (2014). Image acquisition and interpretation criteria for 99mTc-HMPAO-labelled white blood cell scintigraphy: results of a multicentre study. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 41(4), 615-623 [10.1007/s00259-013-2631-4].

Image acquisition and interpretation criteria for 99mTc-HMPAO-labelled white blood cell scintigraphy: results of a multicentre study

Erba, Paola A;
2014

Abstract

Purpose: There is no consensus yet on the best protocol for planar image acquisition and interpretation of radiolabelled white blood cell (WBC) scintigraphy. This may account for differences in reported diagnostic accuracy amongst different centres. Methods: This was a multicentre retrospective study analysing 235 WBC scans divided into two groups. The first group of scans (105 patients) were acquired with a fixed-time acquisition protocol and the second group (130 patients) were acquired with a decay time-corrected acquisition protocol. Planar images were interpreted both qualitatively and semiquantitatively. Three blinded readers analysed the images. Results: The most accurate imaging acquisition protocol comprised image acquisition at 3 - 4 h and at 20 - 24 h in time mode with acquisition times corrected for isotope decay. Conclusion: Using this protocol, visual analysis had high sensitivity and specificity in the diagnosis of infection. Semiquantitative analysis could be used in doubtful cases, with no cut-off for the percentage increase in radiolabelled WBC over time, as a criterion to define a positive scan.
Articolo in rivista - Articolo scientifico
Infection imaging; Scintigraphy; White blood cells;
English
2014
41
4
615
623
reserved
Erba, P., Glaudemans, A., Veltman, N., Sollini, M., Pacilio, M., Galli, F., et al. (2014). Image acquisition and interpretation criteria for 99mTc-HMPAO-labelled white blood cell scintigraphy: results of a multicentre study. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 41(4), 615-623 [10.1007/s00259-013-2631-4].
File in questo prodotto:
File Dimensione Formato  
Erba-2014-Eur J Nucl Med Mol Imaging-VoR.pdf

Solo gestori archivio

Descrizione: Original Article
Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Licenza: Tutti i diritti riservati
Dimensione 2.97 MB
Formato Adobe PDF
2.97 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/426418
Citazioni
  • Scopus 81
  • ???jsp.display-item.citation.isi??? 72
Social impact