Lesion detectability and quantification in fluorine-18-fluorodeoxyglucose positron emission tomography oncological studies are highly affected by space variant blur. The performance of spatial resolution recovery during AWOSEM iterative reconstruction was assessed by including in the system matrix a simple model of point spread function fitted on experi mentally acquired point source sinograms. The model described axial, tangential and radial blur; radial asymmetry was taken into account. The algorithm properties in terms of contrast recovery, image noise and object separability were evaluated on scanned sphere phantom studies both in 2-D and 3-D mode. Extensive comparisons of standard and resolution recovery algorithms, over wide parameter ranges with and without post-filtering are presented. Resolution recovery, by delaying noise breakup appearance and by increasing contrast, was able to improve overall accuracy, particularly for small objects and large blur. The recovery of axial blur resulted determinant in 3-D and even more in 2-D mode. The optimal choice of reconstruction parameters was shown to be highly object dependent, thus suggesting an algorithm tuning according to applications

DE BERNARDI, E., Mazzoli, M., Zito, F., Baselli, G. (2007). Resolution recovery in PET during AWOSEM reconstruction: a performance evaluation study. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 54(5), 1626-1638 [10.1109/TNS.2007.903182].

Resolution recovery in PET during AWOSEM reconstruction: a performance evaluation study

DE BERNARDI, ELISABETTA;
2007

Abstract

Lesion detectability and quantification in fluorine-18-fluorodeoxyglucose positron emission tomography oncological studies are highly affected by space variant blur. The performance of spatial resolution recovery during AWOSEM iterative reconstruction was assessed by including in the system matrix a simple model of point spread function fitted on experi mentally acquired point source sinograms. The model described axial, tangential and radial blur; radial asymmetry was taken into account. The algorithm properties in terms of contrast recovery, image noise and object separability were evaluated on scanned sphere phantom studies both in 2-D and 3-D mode. Extensive comparisons of standard and resolution recovery algorithms, over wide parameter ranges with and without post-filtering are presented. Resolution recovery, by delaying noise breakup appearance and by increasing contrast, was able to improve overall accuracy, particularly for small objects and large blur. The recovery of axial blur resulted determinant in 3-D and even more in 2-D mode. The optimal choice of reconstruction parameters was shown to be highly object dependent, thus suggesting an algorithm tuning according to applications
Articolo in rivista - Articolo scientifico
Image reconstruction, ordered subset expectation maximization (OSEM), positron emission tomography (PET), spatial resolution
English
2007
54
5
1626
1638
none
DE BERNARDI, E., Mazzoli, M., Zito, F., Baselli, G. (2007). Resolution recovery in PET during AWOSEM reconstruction: a performance evaluation study. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 54(5), 1626-1638 [10.1109/TNS.2007.903182].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/42277
Citazioni
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 15
Social impact