This study aims to evaluate the Average Glandular Dose (AGD) and diagnostic performance of CEM versus Digital Mammography (DM) as well as versus DM plus one-view Digital Breast Tomosynthesis (DBT), which were performed in the same patients at short intervals of time. A preventive screening examination in high-risk asymptomatic patients between 2020 and 2022 was performed with two-view Digital Mammography (DM) projections (Cranio Caudal and Medio Lateral) plus one Digital Breast Tomosynthesis (DBT) projection (mediolateral oblique, MLO) in a single session examination. For all patients in whom we found a suspicious lesion by using DM + DBT, we performed (within two weeks) a CEM examination. AGD and compression force were compared between the diagnostic methods. All lesions identified by DM + DBT were biopsied; then, we assessed whether lesions found by DBT were also highlighted by DM alone and/or by CEM. We enrolled 49 patients with 49 lesions in the study. The median AGD was lower for DM alone than for CEM (3.41 mGy vs. 4.24 mGy, p = 0.015). The AGD for CEM was significantly lower than for the DM plus one single projection DBT protocol (4.24 mGy vs. 5.55 mGy, p < 0.001). We did not find a statistically significant difference in the median compression force between the CEM and DM + DBT. DM + DBT allows the identification of one more invasive neoplasm one in situ lesion and two high-risk lesions, compared to DM alone. The CEM, compared to DM + DBT, failed to identify only one of the high-risk lesions. According to these results, CEM could be used in the screening of asymptomatic high-risk patients.

Nicosia, L., Bozzini, A., Pesapane, F., Rotili, A., Marinucci, I., Signorelli, G., et al. (2023). Breast Digital Tomosynthesis versus Contrast-Enhanced Mammography: Comparison of Diagnostic Application and Radiation Dose in a Screening Setting. CANCERS, 15(9) [10.3390/cancers15092413].

Breast Digital Tomosynthesis versus Contrast-Enhanced Mammography: Comparison of Diagnostic Application and Radiation Dose in a Screening Setting

Frassoni, Samuele;Bagnardi, Vincenzo;
2023

Abstract

This study aims to evaluate the Average Glandular Dose (AGD) and diagnostic performance of CEM versus Digital Mammography (DM) as well as versus DM plus one-view Digital Breast Tomosynthesis (DBT), which were performed in the same patients at short intervals of time. A preventive screening examination in high-risk asymptomatic patients between 2020 and 2022 was performed with two-view Digital Mammography (DM) projections (Cranio Caudal and Medio Lateral) plus one Digital Breast Tomosynthesis (DBT) projection (mediolateral oblique, MLO) in a single session examination. For all patients in whom we found a suspicious lesion by using DM + DBT, we performed (within two weeks) a CEM examination. AGD and compression force were compared between the diagnostic methods. All lesions identified by DM + DBT were biopsied; then, we assessed whether lesions found by DBT were also highlighted by DM alone and/or by CEM. We enrolled 49 patients with 49 lesions in the study. The median AGD was lower for DM alone than for CEM (3.41 mGy vs. 4.24 mGy, p = 0.015). The AGD for CEM was significantly lower than for the DM plus one single projection DBT protocol (4.24 mGy vs. 5.55 mGy, p < 0.001). We did not find a statistically significant difference in the median compression force between the CEM and DM + DBT. DM + DBT allows the identification of one more invasive neoplasm one in situ lesion and two high-risk lesions, compared to DM alone. The CEM, compared to DM + DBT, failed to identify only one of the high-risk lesions. According to these results, CEM could be used in the screening of asymptomatic high-risk patients.
Articolo in rivista - Articolo scientifico
Average Glandular Dose; breast cancer screening; Contrast-Enhanced Mammography; Digital Breast Tomosynthesis;
English
22-apr-2023
2023
15
9
2413
none
Nicosia, L., Bozzini, A., Pesapane, F., Rotili, A., Marinucci, I., Signorelli, G., et al. (2023). Breast Digital Tomosynthesis versus Contrast-Enhanced Mammography: Comparison of Diagnostic Application and Radiation Dose in a Screening Setting. CANCERS, 15(9) [10.3390/cancers15092413].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/418143
Citazioni
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
Social impact