Purpose: Preventing fragility fractures by treating osteoporosis may reduce disability and mortality worldwide. Algorithms combining clinical risk factors with bone mineral density have been developed to better estimate fracture risk and possible treatment thresholds. This systematic review supported panel members of the Italian Fragility Fracture Guidelines in recommending the use of best-performant tool. The clinical performance of the three most used fracture risk assessment tools (DeFRA, FRAX, and FRA-HS) was assessed in at-risk patients. Methods: PubMed, Embase, and Cochrane Library were searched till December 2020 for studies investigating risk assessment tools for predicting major osteoporotic or hip fractures in patients with osteoporosis or fragility fractures. Sensitivity (Sn), specificity (Sp), and areas under the curve (AUCs) were evaluated for all tools at different thresholds. Quality assessment was performed using the Quality Assessment of Diagnostic Accuracy Studies-2; certainty of evidence (CoE) was evaluated using the Grading of Recommendations Assessment, Development and Evaluation approach. Results: Forty-three articles were considered (40, 1, and 2 for FRAX, FRA-HS, and DeFRA, respectively), with the CoE ranging from very low to high quality. A reduction of Sn and increase of Sp for major osteoporotic fractures were observed among women and the entire population with cut-off augmentation. No significant differences were found on comparing FRAX to DeFRA in women (AUC 59-88% vs. 74%) and diabetics (AUC 73% vs. 89%). FRAX demonstrated non-significantly better discriminatory power than FRA-HS among men. Conclusion: The task force formulated appropriate recommendations on the use of any fracture risk assessment tools in patients with or at risk of fragility fractures, since no statistically significant differences emerged across different prediction tools.

Adami, G., Biffi, A., Porcu, G., Ronco, R., Alvaro, R., Bogini, R., et al. (2023). A systematic review on the performance of fracture risk assessment tools: FRAX, DeFRA, FRA-HS. JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 46(11), 2287-2297 [10.1007/s40618-023-02082-8].

A systematic review on the performance of fracture risk assessment tools: FRAX, DeFRA, FRA-HS

Biffi, A;Porcu, G;Ronco, R;Corrao, G;
2023

Abstract

Purpose: Preventing fragility fractures by treating osteoporosis may reduce disability and mortality worldwide. Algorithms combining clinical risk factors with bone mineral density have been developed to better estimate fracture risk and possible treatment thresholds. This systematic review supported panel members of the Italian Fragility Fracture Guidelines in recommending the use of best-performant tool. The clinical performance of the three most used fracture risk assessment tools (DeFRA, FRAX, and FRA-HS) was assessed in at-risk patients. Methods: PubMed, Embase, and Cochrane Library were searched till December 2020 for studies investigating risk assessment tools for predicting major osteoporotic or hip fractures in patients with osteoporosis or fragility fractures. Sensitivity (Sn), specificity (Sp), and areas under the curve (AUCs) were evaluated for all tools at different thresholds. Quality assessment was performed using the Quality Assessment of Diagnostic Accuracy Studies-2; certainty of evidence (CoE) was evaluated using the Grading of Recommendations Assessment, Development and Evaluation approach. Results: Forty-three articles were considered (40, 1, and 2 for FRAX, FRA-HS, and DeFRA, respectively), with the CoE ranging from very low to high quality. A reduction of Sn and increase of Sp for major osteoporotic fractures were observed among women and the entire population with cut-off augmentation. No significant differences were found on comparing FRAX to DeFRA in women (AUC 59-88% vs. 74%) and diabetics (AUC 73% vs. 89%). FRAX demonstrated non-significantly better discriminatory power than FRA-HS among men. Conclusion: The task force formulated appropriate recommendations on the use of any fracture risk assessment tools in patients with or at risk of fragility fractures, since no statistically significant differences emerged across different prediction tools.
Articolo in rivista - Articolo scientifico
Fracture risk assessment; Fragility fracture; Secondary prevention; Systematic review;
English
9-apr-2023
2023
46
11
2287
2297
none
Adami, G., Biffi, A., Porcu, G., Ronco, R., Alvaro, R., Bogini, R., et al. (2023). A systematic review on the performance of fracture risk assessment tools: FRAX, DeFRA, FRA-HS. JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 46(11), 2287-2297 [10.1007/s40618-023-02082-8].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/417942
Citazioni
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 8
Social impact